Your browser doesn't support javascript.
loading
The Impact of Daily Processor Use on Adult Cochlear Implant Outcomes: Reexamining the Roles of Duration of Deafness and Age at Implantation.
DeFreese, Andrea J; Lindquist, Nathan R; Shi, Linjie; Holder, Jourdan T; Berg, Katelyn A; Haynes, David S; Gifford, René H.
Afiliación
  • DeFreese AJ; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center.
  • Lindquist NR; Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Shi L; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center.
  • Holder JT; Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Berg KA; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center.
  • Haynes DS; Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Gifford RH; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center.
Otol Neurotol ; 44(7): 672-678, 2023 Aug 01.
Article en En | MEDLINE | ID: mdl-37367733
ABSTRACT

OBJECTIVE:

To quantify the roles and relationships between age at implantation, duration of deafness (DoD), and daily processor use via data logging on speech recognition outcomes for postlingually deafened adults with cochlear implants. STUDY

DESIGN:

Retrospective case review.

SETTING:

Cochlear implant (CI) program at a tertiary medical center. PATIENTS Six-hundred fourteen postlingually deafened adult ears with CIs (mean age, 63 yr; 44% female) were included. MAIN OUTCOME

MEASURES:

A stepwise multiple regression analysis was completed to investigate the combined effects of age, DoD, and daily processor use on CI-aided speech recognition (Consonant-Nucleus-Consonant monosyllables and AzBio sentences).

RESULTS:

Results indicated that only daily processor use was significantly related to Consonant-Nucleus-Consonant word scores ( R2 = 0.194, p < 0.001) and AzBio in quiet scores ( R2 = 0.198, p < 0.001), whereas neither age nor DoD was significantly related. In addition, there was no significant relationship between daily processor use, age at implantation, or DoD and AzBio sentences in noise ( R2 = 0.026, p = 0.005).

CONCLUSIONS:

Considering the clinical factors of age at implantation, DoD, and daily processor use, only daily processor use significantly predicted the ~20% of variance in postoperative outcomes (CI-aided speech recognition) accounted for by these clinical factors.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción del Habla / Implantes Cocleares / Implantación Coclear / Sordera Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Otol Neurotol Asunto de la revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Percepción del Habla / Implantes Cocleares / Implantación Coclear / Sordera Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Otol Neurotol Asunto de la revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Año: 2023 Tipo del documento: Article