Your browser doesn't support javascript.
loading
Parametric maps of spatial two-tissue compartment model for prostate dynamic contrast enhanced MRI - comparison with the standard tofts model in the diagnosis of prostate cancer.
Zhou, Xueyan; Fan, Xiaobing; Chatterjee, Aritrick; Yousuf, Ambereen; Antic, Tatjana; Oto, Aytekin; Karczmar, Gregory S.
Afiliación
  • Zhou X; School of Technology, Harbin University, Harbin, China. zhouxueyan@hrbeu.edu.cn.
  • Fan X; Department of Radiology, University of Chicago, Chicago, IL, 60637, USA. zhouxueyan@hrbeu.edu.cn.
  • Chatterjee A; Department of Radiology, University of Chicago, Chicago, IL, 60637, USA.
  • Yousuf A; Department of Radiology, University of Chicago, Chicago, IL, 60637, USA.
  • Antic T; Department of Radiology, University of Chicago, Chicago, IL, 60637, USA.
  • Oto A; Department of Pathology, University of Chicago, Chicago, IL, 60637, USA.
  • Karczmar GS; Department of Radiology, University of Chicago, Chicago, IL, 60637, USA.
Phys Eng Sci Med ; 46(3): 1215-1226, 2023 Sep.
Article en En | MEDLINE | ID: mdl-37432557
ABSTRACT
The spatial two-tissue compartment model (2TCM) was used to analyze prostate dynamic contrast enhanced (DCE) MRI data and compared with the standard Tofts model. A total of 29 patients with biopsy-confirmed prostate cancer were included in this IRB-approved study. MRI data were acquired on a Philips Achieva 3T-TX scanner. After T2-weighted and diffusion-weighted imaging, DCE data using 3D T1-FFE mDIXON sequence were acquired pre- and post-contrast media injection (0.1 mmol/kg Multihance) for 60 dynamic scans with temporal resolution of 8.3 s/image. The 2TCM has one fast ([Formula see text] and [Formula see text]) and one slow ([Formula see text] and [Formula see text]) exchanging compartment, compared with the standard Tofts model parameters (Ktrans and kep). On average, prostate cancer had significantly higher values (p < 0.01) than normal prostate tissue for all calculated parameters. There was a strong correlation (r = 0.94, p < 0.001) between Ktrans and [Formula see text] for cancer, but weak correlation (r = 0.28, p < 0.05) between kep and [Formula see text]. Average root-mean-square error (RMSE) in fits from the 2TCM was significantly smaller (p < 0.001) than the RMSE in fits from the Tofts model. Receiver operating characteristic (ROC) analysis showed that fast [Formula see text] had the highest area under the curve (AUC) than any other individual parameter. The combined four parameters from the 2TCM had a considerably higher AUC value than the combined two parameters from the Tofts model. The 2TCM is useful for quantitative analysis of prostate DCE-MRI data and provides new information in the diagnosis of prostate cancer.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Próstata / Neoplasias de la Próstata Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Phys Eng Sci Med Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Próstata / Neoplasias de la Próstata Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Phys Eng Sci Med Año: 2023 Tipo del documento: Article País de afiliación: China