Your browser doesn't support javascript.
loading
A comparison of the biomechanical properties of three different lumbar internal fixation methods in the treatment of lumbosacral spinal tuberculosis: finite element analysis.
Liu, Jiantao; Gong, Xi; Wang, Kao; Li, Xingyuan; Zhang, Xiwei; Sun, Jiajun; Zhu, Yihan; Ai, Yixiang; Ren, Jing; Xiu, Jintao; Ji, Wenchen.
Afiliación
  • Liu J; Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China. liujiantao2010xjtu@163.com.
  • Gong X; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Wang K; Medical School of Yan'an University, Yan'an, 716000, China.
  • Li X; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Zhang X; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Sun J; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Zhu Y; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Ai Y; Xi'an Jiaotong University, Xi'an, 710049, China.
  • Ren J; Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China.
  • Xiu J; Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China.
  • Ji W; Department of Orthopedics, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China.
Sci Rep ; 13(1): 11354, 2023 07 13.
Article en En | MEDLINE | ID: mdl-37443369
ABSTRACT
There are various internal fixation methods in treating lumbosacral spinal tuberculosis. The study compared the stability and stress distribution in surrounding tissues/implants, such as discs, endplates and screw-rod internal fixation system, etc. when applying three different lumbar internal fixation methods to treat lumbosacral spinal tuberculosis. A finite element model was constructed and validated. The spinal stability was restored using three

methods:

a titanium cage with lateral double screw-rod fixation (group 1), autologous bone with posterior double screw-rod fixation (group 2), and a titanium cage with posterior double screw-rod fixation (group 3). For comparison, group 4 represented the intact L3-S1 spine. Finally, a load was applied, and the ranges of motion and Von Mises stresses in the cortical endplates, screw-rod internal fixation system and cortical bone around the screws in the different groups were recorded and analyzed. All six ranges of motion (flexion, extension, left/right lateral bending, left/right rotation) of the surgical segment were substantially lower in groups 1 (0.53° ~ 1.41°), 2 (0.68° ~ 1.54°) and 3 (0.55° ~ 0.64°) than in group 4 (4.48° ~ 10.12°). The maximum stress in the screw-rod internal fixation system was clearly higher in group 2 than in groups 1 and 3 under flexion, left/right lateral bending, and left/right rotation. However, in extension, group 1 had the highest maximum stress in the screw-rod internal fixation system. Group 2 had the lowest peak stresses in the cortical endplates in all directions. The peak stresses in the cortical bone around the screws were higher in group 1 and group 2 than in group 3 in all directions. Thus, titanium cage with posterior double screw-rod fixation has more advantages in immediate reconstruction of lumbosacral spinal stability and prevention of screw loosening.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fusión Vertebral / Tuberculosis de la Columna Vertebral Límite: Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fusión Vertebral / Tuberculosis de la Columna Vertebral Límite: Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: China