Your browser doesn't support javascript.
loading
Fluorescence-based absolute quantification of near-infrared probes in tissue extracts for biodistribution analyses.
Iaboni, Margherita; Coppo, Alessandra; Remotti, Davide; Queliti, Roberta; Blasi, Francesco; Bussi, Simona; Cabella, Claudia; Poggi, Luisa.
Afiliación
  • Iaboni M; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy. Electronic address: margherita.iaboni@bracco.com.
  • Coppo A; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Remotti D; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Queliti R; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Blasi F; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Bussi S; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Cabella C; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
  • Poggi L; Bracco Imaging SpA, Centro Ricerche Bracco, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
Anal Biochem ; 677: 115251, 2023 09 15.
Article en En | MEDLINE | ID: mdl-37473979
In recent years, significant progress has been made in the development of fluorescent contrast agents for clinical applications. For the development of a fluorescent probe, it is crucial to evaluate its safety profile, including biodistribution. Specific methods need to be developed for the absolute quantification of fluorescent probes in tissue specimens from animals administered with test compounds in the framework of biodistribution/efficacy/toxicity studies. Here, we describe a new method for the absolute quantification of fluorescent probes in tissue specimens from animals administered with compounds that have absorption and emission wavelength in the Near-Infrared region (600-800 nm). The protocol is based on the standard addition approach in order to minimize the interference of the matrix on the analyte signal causing inaccuracy in the absolute determination of the concentration. The measurement of the fluorescence intensity is done via a microplate reader. The method has been fully validated and applied for the quantification of a fluorescence-guided surgery targeted contrast agent in a Good Laboratory Practice (GLP) biodistribution study. Results clearly demonstrate that this procedure is fully applicable in a preclinical setting and that it overcomes common issues associated with fluorescence signal quantification in tissue extracts.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Extractos de Tejidos / Colorantes Fluorescentes Tipo de estudio: Guideline Límite: Animals Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Extractos de Tejidos / Colorantes Fluorescentes Tipo de estudio: Guideline Límite: Animals Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos