Your browser doesn't support javascript.
loading
Prevalence and management of electrical lead abnormalities in cardiac implantable electronic device leads.
Roberts, Hilary; Matheson, Kara; Sapp, John; Gardner, Martin; Gray, Chris; AbdelWahab, Amir; Lee, David; MacIntyre, Ciorsti; Parkash, Ratika.
Afiliación
  • Roberts H; Department of Medicine, Dalhousie University Faculty of Medicine, Halifax, Nova Scotia, Canada.
  • Matheson K; Research Methods Unit, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Sapp J; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
  • Gardner M; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
  • Gray C; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
  • AbdelWahab A; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
  • Lee D; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
  • MacIntyre C; Department of Medicine, Mayo Clinic, Rochester, Minnesota.
  • Parkash R; Division of Cardiology, Queen Elizabeth II Health Sciences Centre, Halifax, Nova Scotia, Canada.
Heart Rhythm O2 ; 4(7): 417-426, 2023 Jul.
Article en En | MEDLINE | ID: mdl-37520017
Background: Electrical lead abnormalities (ELAs) can result in device malfunction, leading to significant morbidity in patients with cardiac implantable electronic devices (CIEDs). Objective: We sought to determine the prevalence and management of ELAs in patients with CIEDs. Methods: This was a retrospective cohort study of patients implanted with a CIED between 2012 and 2019 at a tertiary care center. The primary outcome was ELA defined as increased capture threshold (≥2× implantation value), decreased sensing (≤0.5 implantation value), change in impedance (>50% over 3 months), or nonphysiologic potentials. A secondary outcome of device clinic utilization was also collected. Results: There were 2996 unique patients (35% female) included with 4600 leads (57% Abbott, 43% Medtronic). ELAs were observed in 135 (3%) leads, including 124 (92%) Abbott and 10 (7%) Medtronic leads (hazard ratio 9.25, P < .001). Mean follow-up was 4.5 ± 2.2 years. ELAs were associated smaller lead French size, atrial location, and Abbott leads. Lead revision was required in 28% of cases. Patients with lead abnormalities had 38% more in-clinic visits per patient year of follow-up compared with those without (P < .001). Conclusion: ELAs were more frequent in certain models, which increased rates of revision and follow-up. Identification of factors that mitigate these abnormalities to improve lead performance are required to improve care for these devices and provide efficient healthcare.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Heart Rhythm O2 Año: 2023 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Heart Rhythm O2 Año: 2023 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos