Your browser doesn't support javascript.
loading
Voltammetric determination of inorganic arsenic in mildly acidified (pH 4.7) groundwaters from Mexico and India.
Eikelboom, Martijn; Wang, Yaxuan; Portlock, Gemma; Gourain, Arthur; Gardner, Joseph; Bullen, Jay; Lewtas, Paul; Carriere, Matthieu; Alvarez, Alexandra; Kumar, Arun; O'Prey, Shane; Tölgyes, Tamás; Omanovic, Dario; Bhowmick, Subhamoy; Weiss, Dominik; Salaun, Pascal.
Afiliación
  • Eikelboom M; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK. Electronic address: martijn.eikelboom@liverpool.ac.uk.
  • Wang Y; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK.
  • Portlock G; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK.
  • Gourain A; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK.
  • Gardner J; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK.
  • Bullen J; Department of Earth Science and Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
  • Lewtas P; School of Science, Edith Cowan University, 270 Joondalup Drive, Joondalup, Western Australia, 6027, Australia.
  • Carriere M; Caminos de Agua, José María Correa 23A, Colonia Santa Cecilia, 37727, San Miguel de Allende, Gto, Mexico.
  • Alvarez A; Caminos de Agua, José María Correa 23A, Colonia Santa Cecilia, 37727, San Miguel de Allende, Gto, Mexico.
  • Kumar A; Mahavir Cancer Sansthan and Research Centre, Phulwarisharif, Patna, 801505, Bihar, India.
  • O'Prey S; Informatic Component Technology, UK.
  • Tölgyes T; Informatic Component Technology, UK.
  • Omanovic D; Division for Marine and Environmental Research, Ruder Boskovic Institute, Bijenicka 54, 10000, Zagreb, Croatia.
  • Bhowmick S; Kolkata Zonal Center CSIR-National Environmental Engineering Research Institute (NEERI), Kolkata, West Bengal, 700107, India.
  • Weiss D; Department of Earth Science and Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
  • Salaun P; School of Environmental Sciences, University of Liverpool, 4 Brownlow Street, L69 3GP, Liverpool, UK. Electronic address: salaun@liv.ac.uk.
Anal Chim Acta ; 1276: 341589, 2023 Oct 02.
Article en En | MEDLINE | ID: mdl-37573093
ABSTRACT
Routine monitoring of inorganic arsenic in groundwater using sensitive, reliable, easy-to-use and affordable analytical methods is integral to identifying sources, and delivering appropriate remediation solutions, to the widespread global issue of arsenic pollution. Voltammetry has many advantages over other analytical techniques, but the low electroactivity of arsenic(V) requires the use of either reducing agents or relatively strong acidic conditions, which both complicate the analytical procedures, and require more complex material handling by skilled operators. Here, we present the voltammetric determination of total inorganic arsenic in conditions of near-neutral pH using a new commercially available 25 µm diameter gold microwire (called the Gold Wirebond), which is described here for the first time. The method is based on the addition of low concentrations of permanganate (10 µM MnO4-) which fulfils two roles (1) to ensure that all inorganic arsenic is present as arsenate by chemically oxidising arsenite to arsenate and, (2) to provide a source of manganese allowing the sensitive detection of arsenate by anodic stripping voltammetry at a gold electrode. Tests were carried out in synthetic solutions of various pH (ranging from 4.7 to 9) in presence/absence of chloride. The best response was obtained in 0.25 M chloride-containing acetate buffer resulting in analytical parameters (limit of detection of 0.28 µg L-1 for 10 s deposition time, linear range up to 20 µg L-1 and a sensitivity of 63.5 nA ppb-1. s-1) better than those obtained in acidic conditions. We used this new method to measure arsenic concentrations in contrasting groundwaters the reducing, arsenite-rich groundwaters of India (West Bengal and Bihar regions) and the oxidising, arsenate-rich groundwaters of Mexico (Guanajuato region). Very good agreement was obtained in all groundwaters with arsenic concentrations measured by inductively coupled plasma-mass spectrometry (slope = +1.029, R2 = 0.99). The voltammetric method is sensitive, faster than other voltammetric techniques for detection of arsenic (typically 10 min per sample including triplicate measurements and 2 standard additions), easier to implement than previous methods (no acidic conditions, no chemical reduction required, reproducible sensor, can be used by non-voltammetric experts) and could enable cheaper groundwater surveying campaigns with in-the-field analysis for quick data reporting, even in remote communities.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE País/Región como asunto: Mexico Idioma: En Revista: Anal Chim Acta Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE País/Región como asunto: Mexico Idioma: En Revista: Anal Chim Acta Año: 2023 Tipo del documento: Article