Your browser doesn't support javascript.
loading
Value of a short non-contrast CMR protocol in MINOCA.
Gatti, Marco; Palmisano, Anna; Gerboni, Mattia; Cau, Riccardo; Pintus, Alessandra; Porcu, Michele; Tore, Davide; Vignale, Davide; Andreis, Alessandro; Bergamasco, Laura; De Ferrari, Gaetano Maria; Esposito, Antonio; Saba, Luca; Fonio, Paolo; Faletti, Riccardo.
Afiliación
  • Gatti M; Radiology Unit, Department of Surgical Sciences, University of Turin, Via Genova 3, 10126, Turin, Italy. m.gatti@unito.it.
  • Palmisano A; Clinical and Experimental Radiology Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, 20132, Milan, Italy.
  • Gerboni M; School of Medicine, Vita-Salute San Raffaele University, Milan, Italy.
  • Cau R; Radiology Unit, Department of Surgical Sciences, University of Turin, Via Genova 3, 10126, Turin, Italy.
  • Pintus A; Department of Radiology, AOU Cagliari, University of Cagliari, Cagliari, Italy.
  • Porcu M; Department of Radiology, AOU Cagliari, University of Cagliari, Cagliari, Italy.
  • Tore D; Department of Radiology, AOU Cagliari, University of Cagliari, Cagliari, Italy.
  • Vignale D; Radiology Unit, Department of Surgical Sciences, University of Turin, Via Genova 3, 10126, Turin, Italy.
  • Andreis A; Clinical and Experimental Radiology Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, 20132, Milan, Italy.
  • Bergamasco L; School of Medicine, Vita-Salute San Raffaele University, Milan, Italy.
  • De Ferrari GM; Division of Cardiology, Department Cardiovascular and Thoracic, Città Della Salute E Della Scienza Hospital, University of Turin, Turin, Italy.
  • Esposito A; Radiology Unit, Department of Surgical Sciences, University of Turin, Via Genova 3, 10126, Turin, Italy.
  • Saba L; Division of Cardiology, Department Cardiovascular and Thoracic, Città Della Salute E Della Scienza Hospital, University of Turin, Turin, Italy.
  • Fonio P; Clinical and Experimental Radiology Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, 20132, Milan, Italy.
  • Faletti R; School of Medicine, Vita-Salute San Raffaele University, Milan, Italy.
Eur Radiol ; 34(2): 994-1002, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37581660
ABSTRACT

OBJECTIVES:

To evaluate the diagnostic performance of a short non-contrast CMR (ShtCMR) protocol relative to a matched standard comprehensive CMR (StdCMR) protocol in patients with myocardial infarction with non-obstructive coronary arteries (MINOCA).

METHODS:

This multicenter retrospective study included patients with a working diagnosis of MINOCA who underwent a StdCMR between January 2019 and December 2020. An expert and a non-expert reader performed a blinded reading with the ShtCMR (long-axis cine images, T2w-STIR, T1- and T2-mapping). A consensus reading of the StdCMR (reference standard) was performed at least 3 months after the ShtCMR reading session. Readers were asked to report the following (1) diagnosis; (2) level of confidence in their diagnosis with the ShtCMR; (3) number of myocardial segments involved, and (4) functional parameters.

RESULTS:

A total of 179 patients were enrolled. The ShtCMR lasted 21 ± 9 min and the StdCMR 45 ± 11 min (p < 0.0001). ShtCMR allowed reaching the same diagnosis as StdCMR in 85% of patients when interpreted by expert readers (rising from 66% for poor confidence to 99% for good, p = 0.0001) and in 73% (p = 0.01) by non-expert ones (60% for poor vs 89% for good confidence, p = 0.0001). Overall, the ShtCMR overestimated the ejection fraction, underestimated cardiac volumes (p < 0.01), and underestimated the number of segments involved by pathology (p = 0.0008) when compared with the StdCMR.

CONCLUSION:

The ShtCMR was found to be a debatable alternative to the StdCMR in patients with MINOCA. Nevertheless, when an experienced reader reaches a good or very good diagnostic confidence using the ShtCMR, the reader may choose to stop the examination, reducing the length of the CMR without affecting the patient's diagnosis. CLINICAL RELEVANCE STATEMENT A short non-contrast CMR protocol may be a viable alternative to standard protocols in selected CMR studies of patients with MINOCA, allowing for faster diagnosis while reducing time and resources and increasing the number of patients who can be scanned. KEY POINTS • The ShtCMR lasted 21 ± 9 min and the StdCMR 45 ± 11 min (p < 0.0001). • In 57% of patients with MINOCA, the experienced reader considers that contrast medium is probably not necessary for diagnosis without affecting the patient's diagnosis (99% of agreement rate between ShtCMR and StdCMR).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infarto del Miocardio / Miocarditis Tipo de estudio: Clinical_trials / Guideline / Observational_studies Límite: Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infarto del Miocardio / Miocarditis Tipo de estudio: Clinical_trials / Guideline / Observational_studies Límite: Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Italia