Comparison of Single Versus Two Non-Compression Miniplates in the Management of Unfavourable Angle Fracture of the Mandible Orginal Research.
Chatterjee, Abhirup; Gunashekhar, Shruti; Karthic, Ramkumar; Karthika, S; Edsor, Effie; Nair, Roopesh U.
Afiliación
  • Chatterjee A; Department of Oral and Maxillofacial Surgery, Rajasthan Dental College and Hospital, Jaipur, Rajasthan, India.
  • Gunashekhar S; Consultant Oral and Maxillofacial Surgeon, Rams Dental Clinic, Ganapthy, Coimbatore and VG Hospitals, Thudiyalur, Tamil Nadu, India.
  • Karthic R; Consultant Oral and Maxillofacial Surgeon, Rams Dental Clinic, Ganapthy, Coimbatore and VG Hospitals, Thudiyalur, Tamil Nadu, India.
  • Karthika S; Pediatric and Preventive Dentistry, PMS College of Dental Science and Research, Venkode, Kerala, India.
  • Edsor E; Department of Oral and Maxillofacial Surgery, Sree Mookambika Institute of Dental Sciences, Kanyakumari, Tamil Nadu, India.
  • Nair RU; Department of Oral and Maxillofacial Surgery, Azeezia College of Dental Science and Research, Kummalloor, Kerala, India.
J Pharm Bioallied Sci ; 15(Suppl 1): S486-S489, 2023 Jul.
Article en En | MEDLINE | ID: mdl-37654259
ABSTRACT

Aim:

To compare the postoperative complications of fixing Mandibular angle fractures with two non-compression mini plates, on the superior and lateral the aspects of the mandible, to the standard technique of using a single non-compression miniplate on the superior border.

Methodology:

Fifty patients with MAF were divided equally into two groups. Patients in Group 1 were secured with two mini plates at the lateral and superior border of the MA using an extraoral approach; for patients in Group 2 a single non-compression miniplate was used via an intraoral extended third molar approach as described by Champy et al. The post-operative complications in both groups were compared statistically.

Results:

The findings of this study revealed that there was no significant difference in postoperative complications between the two groups when fixing MAF with two non-compression mini plates versus the standard technique of using a single non compression miniplate on the superior border of the mandible. However, the surgery time with one miniplate was significantly more than the dual plate approach.

Conclusion:

We advocate using two mini plates to treat an unfavorable angle fracture.