Your browser doesn't support javascript.
loading
Dual Plate Fixation of Periprosthetic Distal Femur Fractures.
Andring, Nicholas A; Kaupp, Shannon M; Henry, Kaitlin A; Helmig, Kathryn C; Babcock, Sharon; Halvorson, Jason J; Pilson, Holly T; Carroll, Eben A.
Afiliación
  • Andring NA; Wake Forest University School of Medicine, Winston-Salem, NC.
J Orthop Trauma ; 38(1): 36-41, 2024 01 01.
Article en En | MEDLINE | ID: mdl-37684010
ABSTRACT

OBJECTIVES:

Dual implants for distal femur periprosthetic fractures is a growing area of interest for these challenging fractures with dual plating (DP) emerging as a viable construct for these injuries. In the current study, an experience with DP constructs is described.

DESIGN:

Retrospective case series with comparison group.

SETTING:

Level 1 academic trauma center. PATIENT SELECTION CRITERIA Adults >50 years old sustaining comminuted OTA/AO 33-A2 or 33-A3 DFPF treated with either DP or a single distal femur locking plating (DFLP). Patients with simple 33-A1 fractures were excluded. Prior to 2018, patients underwent DFLP after which the treatment of choice became DP. OUTCOME MEASURES AND COMPARISONS Reoperation rate, alignment, and complications.

RESULTS:

34 patients treated with DFLP and 38 with DP met inclusion and follow up criteria. Average follow up was 18.2 ± 13.8 months in the DFLP group and 19.8 ± 16.1 months in the DP group ( P = 0.339). The average patient age in the DFLP group was 74.8 ± 7.3 years compared to 75.9 ± 11.3 years in the DP group. There were no statistical differences in demographics, fracture morphology, loss of reduction, or reoperation for any cause ( P >.05). DP patients were more likely to be weight bearing in the twelve-week postoperative period ( P <0.001) and return to their baseline ambulatory status ( P = 0.004) compared to DFLP patients.

CONCLUSIONS:

Dual plating of distal femoral periprosthetic fractures maintained coronal alignment with a low reoperation rate even with immediate weight bearing and these patients regained baseline level of ambulation more reliably as compared to patients treated with a single distal femoral locking plate. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas Periprotésicas / Fracturas del Fémur / Fracturas Femorales Distales Límite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: J Orthop Trauma Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas Periprotésicas / Fracturas del Fémur / Fracturas Femorales Distales Límite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: J Orthop Trauma Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos