Your browser doesn't support javascript.
loading
Performance evaluation of alternate ESR measurement method using BC-780 automated hematology analyzer: a comparison study with the Westergren reference method.
Prompetchara, Eakachai; Parnsamut, Chalisa; Wangviwat, Nathawit; Pitakpolrat, Patrawadee; Chaiwong, Kwanlada; Limpornpukdee, Orakarn; Tanticharoenkarn, Surapat; Ketloy, Chutitorn.
Afiliación
  • Prompetchara E; Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Parnsamut C; Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Wangviwat N; Division of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Pitakpolrat P; Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Chaiwong K; Division of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Limpornpukdee O; Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Tanticharoenkarn S; Division of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Ketloy C; Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Clin Chem Lab Med ; 62(2): 303-311, 2024 Jan 26.
Article en En | MEDLINE | ID: mdl-37732424
ABSTRACT

OBJECTIVES:

Implementation of alternate erythrocyte sedimentation rate (ESR) measurement method is increasing worldwide due to its various advantages. In this study, we aim to evaluate the analytical performance of the BC-780 automated hematology analyzer in measurement of ESR value.

METHODS:

Analyzer performance including precision study, carryover, sample stability and potential interferences are examined. Samples with ESR values spanning the whole analytical ESR range are included for method comparison study. Samples with different hematocrit (Hct) and mean corpuscular volume (MCV) values are also analyzed and compared with the results obtained from the Westergren reference method.

RESULTS:

Precisions and carryover results are consistent with the manufacturers' claim. ESR values do not change significantly in the samples stored at 2-8 °C for 24 h (h) or at room temperature (RT) for 8 h, but significantly decreased (p<0.001) when stored at RT for 24 h. Significant increase in ESR value is documented in samples that are hemolyzed (hemoglobin concentration ranged from 1.28-6.01 g/L) (p=0.010) or lipemic (triglyceride above 4.75 mmol/L) (p=0.001). Method comparison study yields a proportional difference with a regression equation=3.08+ 0.98x. Bland-Altman analysis shows a mean absolute bias of 3.12 mm. The obtained absolute mean biases are below 5 mm in all analytical categories except for the group where MCV>100 fL.

CONCLUSIONS:

Most tested parameters met the manufacturer's specifications and were comparable to the reference method. Despite the presence of positive bias, it falls within acceptable criteria. Extensive validation against potential interferences such as hemolysis/lipemia is still necessary in future.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hematología Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2024 Tipo del documento: Article País de afiliación: Tailandia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hematología Límite: Humans Idioma: En Revista: Clin Chem Lab Med Asunto de la revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Año: 2024 Tipo del documento: Article País de afiliación: Tailandia