Molecularly Imprinted Polymer Interface on Screen-Printed ZnO Nanorod Field Effect Transistors for Serotonin Detection in Clinical Samples.
Sinha, Koel; Chakraborty, Ananya; Ahmed, Zishan; Mukherjee, Piyali; Dutta, Priyanka; Das Mukhopadhyay, Chitrangada; RoyChaudhuri, Chirasree.
Afiliación
  • Sinha K; Centre for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • Chakraborty A; Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • Ahmed Z; Centre for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • Mukherjee P; Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • Dutta P; Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • Das Mukhopadhyay C; Centre for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
  • RoyChaudhuri C; Department of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India.
ACS Biomater Sci Eng ; 9(10): 5886-5899, 2023 Oct 09.
Article en En | MEDLINE | ID: mdl-37747783
ABSTRACT
Ultrasensitive detection of serotonin is crucial for the early diagnosis of several diseases like Parkinson's and Alzheimer's. Most of the existing detection strategies are still not suitable for sensitive point-of-care applications. This study presents direct molecular imprinting of serotonin on the surface of three-dimensional zinc oxide (ZnO) nanorod devices connected in a field effect transistor (FET) configuration to achieve ultrasensitive, real-time, and rapid detection with a convenient and affordable approach, which has significant potential for translation to clinical settings. This strategy has enabled pushing the detection limit to 0.1 fM in a physiological analyte in real time with screen-printed electrodes, thereby resulting in the convenient batch fabrication of sensors for clinical validation. The response of the sensor with the clinical sample has been correlated with that of the gold standard and has been observed to be statistically similar.