Your browser doesn't support javascript.
loading
Efficient formaldehyde sensor based on PtPd nanoparticles-loaded nafion-modified electrodes.
Xu, Shuting; Jiang, Li; Huang, Xiaowei; Ju, Wentao; Liang, Yanxia; Tao, Zhu; Yang, Yumeng; Zhu, Benfeng; Wei, Guoying.
Afiliación
  • Xu S; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Jiang L; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Huang X; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Ju W; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Liang Y; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Tao Z; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Yang Y; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Zhu B; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
  • Wei G; College of Materials and Chemistry, China Jiliang University, Hangzhou, 310018, People's Republic of China.
Nanotechnology ; 35(2)2023 Oct 26.
Article en En | MEDLINE | ID: mdl-37804824
ABSTRACT
The noble metal-based electrochemical sensor design for efficient and stable formaldehyde(FA) detection is important ongoing research. In this paper, PtPd/Nafion/GCE is prepared by electrochemical cyclic voltammetry deposition method based on electrodepositing nanostructured platinum (Pt)-palladium (Pd) nanoparticles in Nafion film-coated glassy carbon electrode (GCE). The influence of deposition parameters and chemical composition (atomic ratio of Pt and Pd) on the electrochemical behaviour of PtPd/Nafion/GCE has been investigated. PtPd/Nafion/GCE displays a remarked electrocatalytic activity for the oxidation of FA and exhibits a linear relationship in the range of 10-5000µM, with a detection limit of 3.3µM in 0.1 M H2SO4solution. It is proved that the detection performance of PtPd/Nafion/GCE electrode is valuable for further application with low detection limit, wide linear range, favourable selectivity and high response.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Nanotechnology Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Nanotechnology Año: 2023 Tipo del documento: Article
...