Your browser doesn't support javascript.
loading
"Triple-low" radiation dose bronchial artery CT angiography before bronchial artery embolisation: a feasibility study.
Du, B; Zhang, W; Shao, X; An, J; Ma, H; Zhao, X; Xu, L; An, D; Tian, Y; Dong, Y; Niu, H.
Afiliación
  • Du B; Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China.
  • Zhang W; Chengde Medical University, Anyuan Road, Chengde, 067000, Hebei, China.
  • Shao X; Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China.
  • An J; Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China.
  • Ma H; Chengde Medical University, Anyuan Road, Chengde, 067000, Hebei, China.
  • Zhao X; Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China.
  • Xu L; Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China.
  • An D; Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China.
  • Tian Y; Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China.
  • Dong Y; Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China.
  • Niu H; Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China. Electronic address: niuht2004@126.com.
Clin Radiol ; 78(12): e1017-e1022, 2023 12.
Article en En | MEDLINE | ID: mdl-37813755
ABSTRACT

AIM:

To explore the feasibility of a "triple-low" dose (low tube voltage, low tube current, and low contrast agent volume) bronchial artery computed tomography (CT) angiography (CTA) to replace routine dose bronchial artery CTA before bronchial artery embolisation (BAE). MATERIALS AND

METHODS:

CTA was obtained from 60 patients with body mass index (BMI) < 30 kg/m2 using a 256 multi-section iCT system, and they were divided into two groups (1) group A 100 kVp, 100 mAs, 50 ml contrast medium (CM); (2) group B 120 kVp, automatic tube current modulation (ACTM), 80 ml CM. CT attenuation of the thoracic aorta, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and subjective image quality scores and traceability scores assessed. The effective radiation dose was calculated.

RESULTS:

The radiation dose was reduced by 79.7% in group A compared to group B (p<0.05). The CT attenuation of the thoracic aorta was increased by approximately 13% in group A compared to group B (p<0.05). Higher image noise, lower SNR, and CNR were obtained in group A compared to group B (all p<0.05). Both subjective image quality scores and traceability scores did not differ between groups A and B (both p>0.05).

CONCLUSION:

It is feasible to use the "triple-low" dose CTA protocol for patients with a body mass index (BMI) < 30 kg/m2. The radiation dose was reduced by 79.7%, and the dose of contrast medium was reduced by 37.5% to ensure the diagnostic value.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias Bronquiales / Angiografía por Tomografía Computarizada Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Clin Radiol Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arterias Bronquiales / Angiografía por Tomografía Computarizada Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Clin Radiol Año: 2023 Tipo del documento: Article País de afiliación: China
...