Your browser doesn't support javascript.
loading
Variability of scan quality and perfusion density in longitudinal optical coherence tomography angiography imaging.
Smith, Corey A; Josey, Vanessa L; West, Michael E; Dyachok, Oksana M; Sharpe, Glen P; Vianna, Jayme R; Rafuse, Paul E; Shuba, Lesya M; Nicolela, Marcelo T; Chauhan, Balwantray C.
Afiliación
  • Smith CA; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada corey.smith@dal.ca.
  • Josey VL; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • West ME; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Dyachok OM; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Sharpe GP; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Vianna JR; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Rafuse PE; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Shuba LM; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
  • Nicolela MT; Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Chauhan BC; Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
Br J Ophthalmol ; 2023 Oct 19.
Article en En | MEDLINE | ID: mdl-37857453
ABSTRACT
BACKGROUND/

AIMS:

Optical coherence tomography angiography (OCT-A) images are subject to variability, but the extent to which learning impacts OCT-A measurements is unknown. We determined whether there is a learning effect in glaucoma patients and healthy controls imaged with OCT-A.

METHODS:

Ninety-one open-angle glaucoma patients and 54 healthy controls were imaged every 4 months over a period of approximately 1 year in this longitudinal cohort study. We analysed 15°×15° scans, centred on the fovea, in one eye of each participant. Two-dimensional projection images for the superficial, intermediate and deep vascular plexuses were exported and binarised after which perfusion density was calculated. Linear mixed-effects models were used to investigate the association between perfusion density and follow-up time.

RESULTS:

The mean (SD) age of glaucoma patients and healthy controls was 67.3 (8.1) years and 62.1 (9.0) years, respectively. There was a significant correlation between perfusion density and scan quality in both glaucoma patients (r=0.50 (95% CI 0.42 to 0.58); p<0.05) and healthy controls (r=0.41 (95% CI 0.29 to 0.52); p<0.05). An increase in perfusion density occurred over time and persisted, even after adjustment for scan quality (1.75% per year (95% CI 1.14 to 2.37), p<0.01).

CONCLUSIONS:

Perfusion density measurements are subject to increasing experience of either the operator or participant, or a combination of both. These findings have implications for the interpretation of longitudinal measurements with OCT-A.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Br J Ophthalmol Año: 2023 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Br J Ophthalmol Año: 2023 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM