Diagnostic Accuracy of MR Spectroscopic Imaging and 18F-FET PET for Identifying Glioma: A Biopsy-Controlled Hybrid PET/MRI Study.
Mauler, Jörg; Lohmann, Philipp; Maudsley, Andrew A; Sheriff, Sulaiman; Hoevels, Moritz; Meissner, Anna-Katharina; Hamisch, Christina; Brunn, Anna; Deckert, Martina; Filss, Christian P; Stoffels, Gabriele; Dammers, Jürgen; Ruge, Maximillian I; Galldiks, Norbert; Mottaghy, Felix M; Langen, Karl-Josef; Shah, N Jon.
Afiliación
  • Mauler J; Institute of Neuroscience and Medicine (INM-3/INM-4/INM-11), Forschungszentrum Juelich, Juelich, Germany; j.mauler@fz-juelich.de.
  • Lohmann P; Institute of Neuroscience and Medicine (INM-3/INM-4/INM-11), Forschungszentrum Juelich, Juelich, Germany.
  • Maudsley AA; Department of Stereotactic and Functional Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Sheriff S; Department of Radiology, Miller School of Medicine, University of Miami, Miami, Florida.
  • Hoevels M; Department of Radiology, Miller School of Medicine, University of Miami, Miami, Florida.
  • Meissner AK; Department of Stereotactic and Functional Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Hamisch C; Department of General Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Brunn A; Department of Stereotactic and Functional Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Deckert M; Institute of Neuropathology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Filss CP; Institute of Neuropathology, University Hospital Düsseldorf and Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • Stoffels G; Institute of Neuropathology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Dammers J; Institute of Neuropathology, University Hospital Düsseldorf and Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • Ruge MI; Institute of Neuroscience and Medicine (INM-3/INM-4/INM-11), Forschungszentrum Juelich, Juelich, Germany.
  • Galldiks N; Department of Nuclear Medicine, RWTH Aachen University Hospital, Aachen, Germany.
  • Mottaghy FM; Institute of Neuroscience and Medicine (INM-3/INM-4/INM-11), Forschungszentrum Juelich, Juelich, Germany.
  • Langen KJ; Institute of Neuroscience and Medicine (INM-3/INM-4/INM-11), Forschungszentrum Juelich, Juelich, Germany.
  • Shah NJ; Department of Stereotactic and Functional Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
J Nucl Med ; 65(1): 16-21, 2024 Jan 02.
Article en En | MEDLINE | ID: mdl-37884332
Contrast-enhanced MRI is the method of choice for brain tumor diagnostics, despite its low specificity for tumor tissue. This study compared the contribution of MR spectroscopic imaging (MRSI) and amino acid PET to improve the detection of tumor tissue. Methods: In 30 untreated patients with suspected glioma, O-(2-[18F]fluoroethyl)-l-tyrosine (18F-FET) PET; 3-T MRSI with a short echo time; and fluid-attenuated inversion recovery, T2-weighted, and contrast-enhanced T1-weighted MRI were performed for stereotactic biopsy planning. Serial samples were taken along the needle trajectory, and their masks were projected to the preoperative imaging data. Each sample was individually evaluated neuropathologically. 18F-FET uptake and the MRSI signals choline (Cho), N-acetyl-aspartate (NAA), creatine, myoinositol, and derived ratios were evaluated for each sample and classified using logistic regression. The diagnostic accuracy was evaluated by receiver operating characteristic analysis. Results: On the basis of the neuropathologic evaluation of tissue from 88 stereotactic biopsies, supplemented with 18F-FET PET and MRSI metrics from 20 areas on the healthy-appearing contralateral hemisphere to balance the glioma/nonglioma groups, 18F-FET PET identified glioma with the highest accuracy (area under the receiver operating characteristic curve, 0.89; 95% CI, 0.81-0.93; threshold, 1.4 × background uptake). Among the MR spectroscopic metabolites, Cho/NAA normalized to normal brain tissue showed the highest diagnostic accuracy (area under the receiver operating characteristic curve, 0.81; 95% CI, 0.71-0.88; threshold, 2.2). The combination of 18F-FET PET and normalized Cho/NAA did not improve the diagnostic performance. Conclusion: MRI-based delineation of gliomas should preferably be supplemented by 18F-FET PET.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Glioma Límite: Humans Idioma: En Revista: J Nucl Med Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Glioma Límite: Humans Idioma: En Revista: J Nucl Med Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos