COVID-19 rapid antigen tests approved for self-testing in Australia: published diagnostic test accuracy studies and manufacturer-supplied information. A systematic review.
Med J Aust
; 219(11): 551-558, 2023 Dec 11.
Article
en En
| MEDLINE
| ID: mdl-37903650
OBJECTIVES: To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA) for self-testing by ambulatory people in Australia; to compare these estimates with values reported by test manufacturers. STUDY DESIGN: Systematic review of publications in any language that reported cross-sectional, case-control, or cohort studies in which the participants were ambulatory people in the community or health care workers in hospitals in whom severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was suspected, and the results of testing self-collected biological samples with a TGA-approved COVID-19 RAT were compared with those of reverse transcription-polymerase chain reaction (RT-PCR) testing for SARS-CoV-2. Estimates of diagnostic accuracy (sensitivity, specificity) were checked and compared with manufacturer estimates published on the TGA website. DATA SOURCES: Publications (to 1 September 2022) identified in the Cochrane COVID-19 Study Register and the World Health Organization COVID-19 research database. Information on manufacturer diagnostic accuracy evaluations was obtained from the TGA website. DATA SYNTHESIS: Twelve publications that reported a total of eighteen evaluations of eight RATs approved by the TGA for self-testing (manufacturers: All Test, Roche, Flowflex, MP Biomedicals, Clungene, Panbio, V-Chek, Whistling) were identified. Five studies were undertaken in the Netherlands, two each in Germany and the United States, and one each in Denmark, Belgium, and Canada; test sample collection was unsupervised in twelve studies, and supervised by health care workers or researchers in six. Estimated sensitivity with unsupervised sample collection ranged from 20.9% (MP Biomedicals) to 74.3% (Roche), and with supervised collection from 7.7% (V-Chek) to 84.4% (Panbio); the estimates were between 8.2 and 88 percentage points lower than the values reported by the manufacturers. Test specificity was high for all RATs (97.9-100%). CONCLUSIONS: The risk of false negative results when using COVID-19 RATs for self-testing may be considerably higher than apparent in manufacturer reports on the TGA website, with implications for the reliability of these tests for ruling out infection.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
COVID-19
Tipo de estudio:
Systematic_reviews
Límite:
Humans
Idioma:
En
Revista:
Med J Aust
Año:
2023
Tipo del documento:
Article
Pais de publicación:
Australia