Your browser doesn't support javascript.
loading
Efficacy of Whole-Blood Model of Gadolinium-Based Contrast Agent Relaxivity in Predicting Vascular MR Signal Intensity In Vivo.
Norris, Evan C; Schneider, Guenther; Clark, Toshimasa J; Kirchin, Miles A; Wilson, Gregory J; Maki, Jeffrey H.
Afiliación
  • Norris EC; Department of Radiology, University of Colorado Anschutz Medical Center, Aurora, Colorado, USA.
  • Schneider G; Department of Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg, Germany.
  • Clark TJ; Department of Radiology, University of Colorado Anschutz Medical Center, Aurora, Colorado, USA.
  • Kirchin MA; Global Medical & Regulatory Affairs, Bracco Imaging SpA, Milan, Italy.
  • Wilson GJ; Department of Radiology, University of Washington, Seattle, Washington, USA.
  • Maki JH; Department of Radiology, University of Colorado Anschutz Medical Center, Aurora, Colorado, USA.
J Magn Reson Imaging ; 2023 Nov 02.
Article en En | MEDLINE | ID: mdl-37916957
ABSTRACT

BACKGROUND:

Previous in vitro studies have described sub-linear longitudinal and heightened transverse H2 O relaxivities of gadolinium-based contrast agents (GBCAs) in blood due to their extracellular nature. However, in vivo validation is lacking.

PURPOSE:

Validate theory describing blood behavior of R1 and R2 * in an animal model. STUDY TYPE Prospective, animal. ANIMAL MODEL Seven swine (54-65 kg). FIELD STRENGTH/SEQUENCE 1.5 T; time-resolved 3D spoiled gradient-recalled echo (SPGR) and quantitative Look-Locker and multi-echo fast field echo sequences. ASSESSMENT Seven swine were each injected three times with 0.1 mmol/kg intravenous doses of one of three GBCAs gadoteridol, gadobutrol, and gadobenate dimeglumine. Injections were randomized for rate (1, 2, and 3 mL/s) and order, during which time-resolved aortic 3D SPGR imaging was performed concurrently with aortic blood sampling via an indwelling catheter. Time-varying [GBCA] was measured by mass spectrometry of sampled blood. Predicted signal intensity (SI) was determined from a model incorporating sub-linear R1 and R2 * effects (whole-blood model) and simpler models incorporating linear R1 , with and without R2 * effects. Predicted SIs were compared to measured aortic SI. STATISTICAL TESTS Linear correlation (coefficient of determination, R2 ) and mean errors were compared across the SI prediction models.

RESULTS:

There was an excellent correlation between predicted and measured SI across all injections and swine when accounting for the non-linear dependence of R1 and high blood R2 * (regression slopes 0.91-1.04, R2 ≥ 0.91). Simplified models (linear R1 with and without R2 * effects) showed poorer correlation (slopes 0.67-0.85 and 0.54-0.64 respectively, both R2 ≥ 0.89) and higher averaged mean absolute and mean square errors (128.4 and 177.4 vs. 42.0, respectively, and 5506 and 11,419 vs. 699, respectively). DATA

CONCLUSION:

Incorporating sub-linear R1 and high first-pass R2 * effects in arterial blood models allows accurate SPGR SI prediction in an in vivo animal model, and might be utilized when modeling MR blood SI. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY Stage 1.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos