Your browser doesn't support javascript.
loading
Estimation of the number of single-photon emitters for multiple fluorophores with the same spectral signature.
Li, Wenchao; Li, Shuo; Brown, Timothy C; Sun, Qiang; Wang, Xuezhi; Yakovlev, Vladislav V; Kealy, Allison; Moran, Bill; Greentree, Andrew D.
Afiliación
  • Li W; School of Science, RMIT University, Melbourne, VIC 3001, Australia.
  • Li S; ARC Centre of Excellence for Nanoscale BioPhotonics, RMIT University, Melbourne, VIC 3001, Australia.
  • Brown TC; School of Mathematics, Monash University, Melbourne, VIC 3800, Australia.
  • Sun Q; ARC Centre of Excellence for Nanoscale BioPhotonics, RMIT University, Melbourne, VIC 3001, Australia.
  • Wang X; School of Science, RMIT University, Melbourne, VIC 3001, Australia.
  • Yakovlev VV; Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
  • Kealy A; School of Engineering, RMIT University, Melbourne, VIC 3001, Australia.
  • Greentree AD; ARC Centre of Excellence for Nanoscale BioPhotonics, RMIT University, Melbourne, VIC 3001, Australia.
AVS Quantum Sci ; 5(4): 041401, 2023 Dec.
Article en En | MEDLINE | ID: mdl-38053619
ABSTRACT
Fluorescence microscopy is of vital importance for understanding biological function. However, most fluorescence experiments are only qualitative inasmuch as the absolute number of fluorescent particles can often not be determined. Additionally, conventional approaches to measuring fluorescence intensity cannot distinguish between two or more fluorophores that are excited and emit in the same spectral window, as only the total intensity in a spectral window can be obtained. Here we show that, by using photon number resolving experiments, we are able to determine the number of emitters and their probability of emission for a number of different species, all with the same measured spectral signature. We illustrate our ideas by showing the determination of the number of emitters per species and the probability of photon collection from that species, for one, two and three otherwise unresolvable fluorophores. The convolution binomial model is presented to represent the counted photons emitted by multiple species. Then, the expectation-maximization (EM) algorithm is used to match the measured photon counts to the expected convolution binomial distribution function. In applying the EM algorithm, to leverage the problem of being trapped in a sub-optimal solution, the moment method is introduced to yield an initial guess for the EM algorithm. Additionally, the associated Cramér-Rao lower bound is derived and compared with the simulation results.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: AVS Quantum Sci Año: 2023 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: AVS Quantum Sci Año: 2023 Tipo del documento: Article País de afiliación: Australia