Your browser doesn't support javascript.
loading
Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study.
Oh, Chahyun; Baek, Sujin; Lee, Soomin; Shim, Man-Shik; Han, Sung Joon; Kim, Yoon-Hee; Lee, Jeong Yeon; Ku, Yunseo; Hong, Boohwi.
Afiliación
  • Oh C; Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, 282 Munhwa-ro, Jung-gu, Daejeon, 35015, Korea.
  • Baek S; Department of Anesthesiology and Pain Medicine, Chungnam National University College of Medicine, Daejeon, Korea.
  • Lee S; Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, 282 Munhwa-ro, Jung-gu, Daejeon, 35015, Korea.
  • Shim MS; Department of Anesthesiology and Pain Medicine, Chungnam National University College of Medicine, Daejeon, Korea.
  • Han SJ; Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, 282 Munhwa-ro, Jung-gu, Daejeon, 35015, Korea.
  • Kim YH; Department of Anesthesiology and Pain Medicine, Chungnam National University College of Medicine, Daejeon, Korea.
  • Lee JY; Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital, Daejeon, Korea.
  • Ku Y; Department of Thoracic and Cardiovascular Surgery, Chungnam National University Hospital, Daejeon, Korea.
  • Hong B; Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, 282 Munhwa-ro, Jung-gu, Daejeon, 35015, Korea.
Sci Rep ; 13(1): 21704, 2023 12 07.
Article en En | MEDLINE | ID: mdl-38066206
ABSTRACT
Although previous studies have shown correlation between regional cerebral oxygen saturation (rScO2) and mixed venous oxygen saturation (SvO2), there is a lack of pragmatic information on the clinical applicability of these findings, such as tracking ability. We retrospectively analyzed continuous intraoperative recordings of rScO2 and SvO2 obtained from a pulmonary artery catheter and either of two near-infrared spectroscopy (NIRS) devices (INVOS 5100C, Medtronic; O3, Masimo) during off-pump cardiopulmonary bypass (OPCAB) surgery in adult patients. The ability of rScO2 to track SvO2 was quantitatively evaluated with 5 min interval changes transformed into relative values. The analysis included 176 h of data acquired from 48 subjects (26 and 22 subjects for INVOS and O3 dataset, respectively). The area under ROC of the left-rScO2 for detecting change of SvO2 ≥ 10% in INVOS and O3 datasets were 0.919 (95% CI 0.903-0.936) and 0.852 (95% CI 0.818-0.885). The concordance rates between the interval changes of left-rScO2 and SvO2 in INVOS and O3 datasets were 90.6% and 91.9% with 10% exclusion zone. rScO2 can serve as a noninvasive tool for detecting changes in SvO2 levels, a critical hemodynamic measurement.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oxígeno / Espectroscopía Infrarroja Corta Límite: Adult / Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oxígeno / Espectroscopía Infrarroja Corta Límite: Adult / Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article
...