Your browser doesn't support javascript.
loading
Entrance surface air kerma to patients during digital radiographic examinations in Tanzania.
Makoba, Atumaini; Jusabani, Ahmed; Muhogora, Wilbroad; Kileo, Abdallah; Ndukeki, Musa; Makungu, Hilda; Maro, Haika; Onoka, Erick; Ngulimi, Miguta; Mammba, Huruma; Muhulo, Alex; Masoud, Ali; Balobegwa, Vitus; Ngoye, Wilson; Nakembetwa, Adam.
Afiliación
  • Makoba A; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Jusabani A; Aga Khan Medical Centre, Baraka Obama Drive, 11102 Dar es Salaam, Tanzania.
  • Muhogora W; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Kileo A; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Ndukeki M; Muhimbili National Hospital, Kalenga Road, 11103 Dar es Salaam, Tanzania.
  • Makungu H; Muhimbili National Hospital, Kalenga Road, 11103 Dar es Salaam, Tanzania.
  • Maro H; Mbeya Zonal Referral Hospital, Hospital Hill Road, Mbeya, Tanzania.
  • Onoka E; Arusha Lutheran Medical Centre, Fr. Babu Road, Block No.54 Levolosi, Arusha, Tanzania.
  • Ngulimi M; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Mammba H; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Muhulo A; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Masoud A; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Balobegwa V; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Ngoye W; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
  • Nakembetwa A; Tanzania Atomic Energy Commission, Block J, Njiro, 23114 Arusha, Tanzania.
Radiat Prot Dosimetry ; 200(3): 229-239, 2024 Mar 02.
Article en En | MEDLINE | ID: mdl-38069535
ABSTRACT
The aim of this study was to determine the entrance surface air kerma (ESAK) in adult patients during digital radiography and to evaluate the optimisation potential in five common X-ray examinations in Tanzania. Based on a sample of 240-610 patients, ESAK was estimated using X-ray tube output measurements, patient information and backscatter factors. The results show that the mean ESAK values were higher or comparable to data from the literature. The diagnostic reference values of ESAK for digital radiography were 0.31 mGy (chest PA), 4 mGy (lumbar spine AP), 5.4 mGy (lumbar spine LAT), 3.8 mGy (abdomen AP) and 2.4 mGy (pelvis AP). For computed radiography, the mean ESAK ranges were 0.44-0.57 mGy (thoracic AP), 3.59-3.72 mGy (lumbar spine AP), 6.16-6.35 mGy (lumbar spine LAT), 3.89-3.44 mGy (abdominal AP) and 2.92-3.47 mGy (pelvic AP). In conclusion, high ESAK variations show the potential for optimising protection in digital radiology.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Intensificación de Imagen Radiográfica / Vértebras Lumbares Límite: Adult / Humans País/Región como asunto: Africa Idioma: En Revista: Radiat Prot Dosimetry Año: 2024 Tipo del documento: Article País de afiliación: Tanzania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Intensificación de Imagen Radiográfica / Vértebras Lumbares Límite: Adult / Humans País/Región como asunto: Africa Idioma: En Revista: Radiat Prot Dosimetry Año: 2024 Tipo del documento: Article País de afiliación: Tanzania