Your browser doesn't support javascript.
loading
Robust Organogel Scintillator for Self-healing and Ultra-flexible X-ray Imaging.
Liu, Lulu; Hu, Haijing; Pan, Wanting; Gao, Hang; Song, Jinmei; Feng, Xiaopeng; Qu, Wei; Wei, Wei; Yang, Bai; Wei, Haotong.
Afiliación
  • Liu L; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Hu H; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Pan W; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Gao H; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Song J; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Feng X; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Qu W; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Wei W; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, P. R. China.
  • Yang B; State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
  • Wei H; Optical Functional Theragnostic Joint Laboratory of Medicine and Chemistry, The First Hospital of Jilin University, Changchun, 130012, P. R. China.
Adv Mater ; 36(13): e2311206, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38104266
ABSTRACT
Metal halide scintillators serve as promising candidates for X-ray detection due to their high attenuation coefficients, high light yields, and low-cost solution-processable characteristics. However, the issues of humidity/thermal quenching and mechanical fragility, remain obstacles to the broad and diversified development of metal halide scintillators. Here, this work reports a lead-free, water-stable, stretchable, and self-healing (ethylenebis-triphenylphosphonium manganese (II) bromide (C38H34P2)MnBr4 organogel scintillator that meets X-ray imaging in complex scenarios. The robust organogel scintillator can be stretched with elongation up to 1300% while maintaining the scintillation properties. Activated by the dynamic hydrogen bonds and coordination bonds design, the organogel scintillator exhibits excellent self-healing properties at room temperature to alleviate the vignetting problem of the rigid scintillator films, the X-ray imaging resolution can reach 16.7 lp mm-1. The organogel scintillator can also realize flexible and self-healing X-ray imaging in water, providing a design path for portable devices in harsh conditions.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Adv Mater Asunto de la revista: BIOFISICA / QUIMICA Año: 2024 Tipo del documento: Article Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Adv Mater Asunto de la revista: BIOFISICA / QUIMICA Año: 2024 Tipo del documento: Article Pais de publicación: Alemania