Your browser doesn't support javascript.
loading
Radiographic Assessment of Cleft Alveolar Bone Defects: A Preliminary Comparison of Periapical and Cone Beam Computed Tomography Images.
Guo, Yiou; Woodyard De Brito, Kiersten C; Gosnell, Elizabeth S; Sun, Qin; Wang, Jue.
Afiliación
  • Guo Y; College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
  • Woodyard De Brito KC; Division of Pediatric Dentistry and Orthodontics, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
  • Gosnell ES; College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
  • Sun Q; Division of Pediatric Plastic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
  • Wang J; College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
Cleft Palate Craniofac J ; : 10556656231220507, 2023 Dec 17.
Article en En | MEDLINE | ID: mdl-38105594
ABSTRACT
BACKGROUND &

PURPOSE:

Accurate radiographic assessment of secondary alveolar bone grafting (SABG) is critical in evaluating SABG outcomes in patients with cleft lip and palate. This study compared Periapical (PA) and Cone beam computed tomography (CBCT) grading of SABG outcomes and conducted an analysis of agreement rate between the two imaging modalities.

METHODS:

A retrospective chart review was performed of patients who underwent secondary alveolar bone grafting at a single institution. Bone quality of the alveolar cleft site was assessed at three root levels of the adjacent teeth on PA and CBCT images.

RESULTS:

48 patients had pre- or post-operative images with both CBCT and PA that were appropriate for comparison. A total of 174 alveolar bone sections (three root levels of adjacent teeth in 58 pairs) were graded on CBCT and PA images. Agreement of CBCT grading with PA grading was 41.3% (72/174) overall. CBCT assessments rated bone quality lower than PA grading in 51.2% (89/174) of sections. CBCT had higher grading than PA image grading in 7.5% (13/174) of sections. The weighted Cohen Kappa value for comparison of CBCT and PA readings was 0.17, indicating a low rate of agreement. Wilcoxon signed rank test demonstrated that the difference between grading on CBCT and PA assessments was statistically significant (P < .001).

CONCLUSIONS:

CBCT and PA readings demonstrated an overall low rate of agreement in the assessment of cleft alveolar bone. This investigation suggests that PA radiographs have lower sensitivity in detecting poor bone grafting outcomes.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Cleft Palate Craniofac J Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Cleft Palate Craniofac J Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos