Your browser doesn't support javascript.
loading
The value of a deep learning image reconstruction algorithm in whole-brain computed tomography perfusion in patients with acute ischemic stroke.
Lei, Limin; Zhou, Yuhan; Guo, Xiaoxu; Wang, Luotong; Zhao, Xitong; Wang, Hui; Ma, Jinping; Yue, Songwei.
Afiliación
  • Lei L; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Zhou Y; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Guo X; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Wang L; GE HealthCare China, Beijing, China.
  • Zhao X; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Wang H; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Ma J; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
  • Yue S; Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Quant Imaging Med Surg ; 13(12): 8173-8189, 2023 Dec 01.
Article en En | MEDLINE | ID: mdl-38106310
ABSTRACT

Background:

Computed tomography perfusion (CTP) and computed tomography angiography (CTA) are valuable tools for diagnosing acute ischemic stroke (AIS). It is essential to obtain high-quality CTP and CTA images in short time. This study aimed to evaluate the image quality and diagnostic performance of brain CTP and CTA images generated from CTP reconstructed by a deep learning image reconstruction (DLIR) algorithm on patients with AIS.

Methods:

The study prospectively enrolled 54 patients with suspected AIS undergoing non-contrast CT and CTP within 24 hours. CTP datasets were reconstructed with three levels of adaptive statistical iterative reconstruction-Veo algorithm [ASIR-V 0% with filtered back projection (FBP), ASIR-V 40%, and ASIR-V 80%] and three levels of DLIR, including low (DLIR-L), medium (DLIR-M), and high (DLIR-H). CTA images were generated using the CTP datasets at the peak arterial phase. Objective parameters including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and noise reduction rate. Subjective evaluation was assessed according to Abels scoring system. Perfusion parameters and detection accuracy for infarction core lesions were evaluated. The objective and subjective image quality of CTA images were also evaluated.

Results:

All reconstructions produced similar CT values (P>0.05). With the increase of ASIR-V and DLIR reconstruction strength, image noise decreased, while SNR and CNR increased for CTP images, especially in white matter. DLIR-H, DLIR-M, and ASIR-V80% yielded higher subjective scores than did ASIR-V40% and FBP. DLIR-H provided the highest noise reduction rate and detection accuracy. No significant difference was found in conventional parameters, the volume of infarct core, or ischemic penumbra among the 6 groups (P>0.05). The objective evaluation of reconstructed CTA images was comparable in DLIR-H, DLIR-M, and ASIR-V80% (P>0.05). The subjective scores of the DLIR-H and DLIR-M images were higher than those of the other groups, especially ASIR-V40% and FBP (P<0.05).

Conclusions:

Compared with FBP and ASIR-V40%, DLIR-H, DLIR-M, and ASIR-V80% improved the overall image quality of CTP and CTA images to varying degrees. Furthermore, DLIR-H and DLIR-M showed the best performance. DLIR-H is the best choice in diagnosing AIS with improved detection accuracy for cerebral infarction. Reconstructing CTA images using CTP datasets could reduce contrast agent and radiation dose.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2023 Tipo del documento: Article País de afiliación: China