Your browser doesn't support javascript.
loading
Difference in SII provided by initial fit and NAL-NL2 and its relation to self-reported hearing aid outcomes.
Narayanan, Sreeram K; Rye, Palle; Houmøller, Sabina Storbjerg; Wolff, Anne; Hougaard, Dan Dupont; Gaihede, Michael; Schmidt, Jesper Hvass; Hammershøi, Dorte.
Afiliación
  • Narayanan SK; Department of Electronic Systems, Section for AI and Sound, Aalborg University, Aalborg, Denmark.
  • Rye P; Department of Electronic Systems, Section for AI and Sound, Aalborg University, Aalborg, Denmark.
  • Houmøller SS; Research Unit for ORL - Head & Neck Surgery and Audiology, Odense University Hospital & University of Southern Denmark, Odense, Denmark.
  • Wolff A; OPEN, Odense Patient data Explorative Network, Odense University Hospital, Odense, Denmark.
  • Hougaard DD; Department of Otolaryngology, Head & Neck Surgery and Audiology, Aalborg University Hospital, Aalborg, Denmark.
  • Gaihede M; Department of Otolaryngology, Head & Neck Surgery and Audiology, Aalborg University Hospital, Aalborg, Denmark.
  • Schmidt JH; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
  • Hammershøi D; Department of Otolaryngology, Head & Neck Surgery and Audiology, Aalborg University Hospital, Aalborg, Denmark.
Int J Audiol ; : 1-8, 2023 Dec 19.
Article en En | MEDLINE | ID: mdl-38112025
ABSTRACT

OBJECTIVE:

The speech intelligibility index (SII) is used to quantify the audibility of the speech. This study examined the relationship between self-reported hearing aid (HA) outcomes and the difference in aided SII (SIIA) calculated from the initial fit (IF) gain and that prescribed as per the second generation of National Acoustic Laboratory Non-Linear (NAL-NL2).

DESIGN:

A prospective observational study. STUDY SAMPLE The study included 718 first-time and 253 experienced HA users. All users had a valid real-ear measurement (REM) at three input levels (55, 65 and 80 dB SPL).

RESULTS:

The gain provided by IF was lower than NAL-NL2 at 55 and 65 dB SPL. IF gain exhibited reduced compression than NAL-NL2 as input levels increased from 55 to 80 dB SPL. On average, the SIIA provided by IF was significantly lower than that for NAL-NL2 at all input levels. The difference in SIIA between IF and NAL-NL2 at 80 dB SPL input level with 0 dB signal-to-noise ratio (SNR) turned out to be a predictor for self-reported outcome for first-time HA users.

CONCLUSION:

The study suggests that an SIIA close to that provided by NAL-NL2 at high input levels would be preferred to obtain a better self-reported outcome. .
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Audiol Asunto de la revista: AUDIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Int J Audiol Asunto de la revista: AUDIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Dinamarca