Your browser doesn't support javascript.
loading
Study of the f-cell ratio using plasma dilution and albumin mass kinetics.
Hahn, Robert G.
Afiliación
  • Hahn RG; Department of Clinical Sciences at Danderyd Hospital (KIDS), Karolinska Institutet, Stockholm, Sweden. Electronic address: robert.hahn@ki.se.
Microvasc Res ; 152: 104649, 2024 03.
Article en En | MEDLINE | ID: mdl-38123066
ABSTRACT

BACKGROUND:

The f-cell ratio of 0.91 is a conversion factor between the hematocrit measured in peripheral blood and the hematocrit obtained by separate measurements of the red blood cell mass and plasma volume. The physiological background of the f-cell ratio is unclear.

METHODS:

Data were retrieved from 155 intravenous infusion experiments where 15-25 mL/kg of crystalloid fluid diluted the blood hemoglobin and plasma albumin concentrations. The hemodilution was converted to plasma dilution using the peripheral hematocrit, and the volume of distribution of exogenous albumin was calculated in 41 volunteers who received 20 % or 5 % albumin by intravenous infusion. Finally, the kinetics of plasma albumin was studied during 98 infusion experiments with 20 % albumin.

RESULTS:

Plasma dilution based on hemoglobin and albumin showed a median difference of -0.001 and a mean difference of 0.000 (N = 2184), which demonstrates that these biomarkers indicate the same expandable vascular space. In contrast, exogenous albumin occupied a volume that was 10 % larger than the plasma volume indicated by the anthropometric equations of Nadler et al. and Retzlaff et al. The kinetic analysis identified a secondary compartment that was 450 mL in size and rapidly exchanged albumin with the circulating plasma.

CONCLUSIONS:

The results suggest that the f-cell ratio is due to rapid exchange of albumin between the plasma and a non-expandable compartment located outside the circulating blood (possibly the liver sinusoids). This means that the hematocrit measured in peripheral blood correctly represents the ratio between the red cell volume and the circulating plasma volume.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Volumen Sanguíneo / Volumen de Eritrocitos Límite: Humans Idioma: En Revista: Microvasc Res Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Volumen Sanguíneo / Volumen de Eritrocitos Límite: Humans Idioma: En Revista: Microvasc Res Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos