Your browser doesn't support javascript.
loading
Eucapnic pH coupled with arterial cord pH improves hypoxic-ischemic encephalopathy prediction.
Gauci, Pierre-Alexis; Racinet, Claude; Ouellet, Paul; Daboval, Thierry; Trolli, Sergio Eleni Dit; Delotte, Jérôme.
Afiliación
  • Gauci PA; Department of Obstetrics and Gynecology, Reproduction and Fetal Medicine CHU de Nice, University of Côte d'Azur, Nice, France.
  • Racinet C; RHEOP, Grenoble, France.
  • Ouellet P; Vitalité Health Network, Northwest zone, Adjunct Professor (Ret.), Department of Surgery, Sherbrooke University, Sherbrooke, Quebec, Canada.
  • Daboval T; Department of Neonatology, Ottawa University, Ottawa, Ontario, Canada.
  • Trolli SED; Department of Obstetrics and Gynecology, Reproduction and Fetal Medicine CHU de Nice, University of Côte d'Azur, Nice, France.
  • Delotte J; Department of Obstetrics and Gynecology, Reproduction and Fetal Medicine CHU de Nice, University of Côte d'Azur, Nice, France.
Int J Gynaecol Obstet ; 165(3): 1114-1121, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38193307
ABSTRACT

OBJECTIVE:

To consider the classical use of "pH < 7.0 and/or a base deficiency ≥12 mmol/L" as markers of the risk of neonatal hypoxic-ischemic encephalopathy (HIE), recalling various criticisms of the use of these markers in favor of that of neonatal eucapnic pH, which appears to be a better marker of this risk.

METHODS:

Fifty-five cases of acidemia with pH < 7.00 were collected from a cohort from the Nice University Hospital with eight cases of HIE. We compared the receiver operating characteristics curves established from the positive likelihood ratio (+LR) for each case of umbilical cord artery pH (pHa), neonatal eucapnic pH (pH euc-n) in isolation (not matched to pHa), and matched pHa to its own pH euc-n.

RESULTS:

The areas under the curve (AUC) are identical for pHa and pH euc-n, but AUC for the matched pair pHa-pH euc-n appears superior but non-significant because of the small number in our cohort. However, using the bootstrap method, the partial AUC for a sensitivity greater than 75% indicates the significant superiority (P < 0.01) of the matched pair pHa-pH euc-n approach.

CONCLUSION:

The originality of this study lies in the use of two methodologic approaches (1) standardized partial analysis of the AUCs of the pHa curve and that of pHa matched to its own pH euc-n, and (2) bootstrap statistical technique, that allowed us to conclude (P < 0.01) that the combined use of pH measured at the cord coupled with its eucapnic correction is better for diagnosing metabolic acidosis and best predicting the risk of HIE.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hipoxia-Isquemia Encefálica / Sangre Fetal Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Newborn / Pregnancy Idioma: En Revista: Int J Gynaecol Obstet Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hipoxia-Isquemia Encefálica / Sangre Fetal Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male / Newborn / Pregnancy Idioma: En Revista: Int J Gynaecol Obstet Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Estados Unidos