Your browser doesn't support javascript.
loading
Digital microscope-assisted photography improves the accuracy of mosquito wing measurement.
Zulzahrin, Zulhisham; Wong, Meng Li; Naziri, Mohd Redzuan Ahmad; Lau, Yee-Ling; Vythilingam, Indra; Lee, Wenn-Chyau.
Afiliación
  • Zulzahrin Z; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Wong ML; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Naziri MRA; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Lau YL; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Vythilingam I; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Lee WC; Department of Parasitology, Faculty of Medicine, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
Heliyon ; 10(3): e25207, 2024 Feb 15.
Article en En | MEDLINE | ID: mdl-38322922
ABSTRACT
Wing measurement is an important parameter in many entomological studies. However, the methods of measuring wings vary with studies, and a gold standard method was not available for this procedure. This in turn limits researchers from confidently comparing their research findings with published data collected by other means of measurement. This study investigated the interchangeability of three commonly available methods for wing measurement, namely the calliper method, stereomicroscope-assisted photography method, and digital microscope-assisted photography method, using the laboratory colony of Aedes aegypti. It was found that the calliper method and the photography-based methods yielded similar results, hence the good interchangeability of these methods. Nevertheless, the digital microscope-assisted photography method yielded more accurate measurements, due to the higher resolution of the captured photos, and minimal technical bias during the data collection, as compared to the calliper-based and stereomicroscope-assisted photography methods. This study served as a reference for researchers to select the most suitable measurement method in future studies.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2024 Tipo del documento: Article País de afiliación: Malasia