Your browser doesn't support javascript.
loading
Method, safety, and outcomes of persistent AF ablation without a circular mapping catheter: 3 years experience of a Belgian Tertiary Centre.
Robaye, Benoit; Deceuninck, Olivier; Blommaert, Dominique; Godeaux, Veronique; Dormal, Fabien; Collet, Benoit; Ballant, Elisabeth; Huys, Florence; Purnode, Philippe; Xhaët, Olivier.
Afiliación
  • Robaye B; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Deceuninck O; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Blommaert D; Department of Cardiology, CHR Namur, Namur, Belgium.
  • Godeaux V; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Dormal F; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Collet B; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Ballant E; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Huys F; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Purnode P; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
  • Xhaët O; Service de Cardiologie, Université Catholique de Louvain, CHU UCL Namur, Yvoir, Belgium.
Acta Cardiol ; 79(5): 591-598, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38334112
ABSTRACT

BACKGROUND:

We aimed to share our methods and experience of persistent AF ablation without a circular mapping catheter (CMC), thereby avoiding femoral venous and transseptal punctures, decreasing the cost of the procedure, and possibly reducing the duration of the procedure and fluoroscopy time.

METHODS:

We report our experience with 261 persistent AF ablations performed without a CMC over the past 3 years.

RESULTS:

The procedures were performed with no apparent loss of efficacy or safety. Freedom from recurrence was defined as a 1-year absence of AF/atrial flutter (AFL) episodes >30 s, beyond the 3-month blanking period. At 1 year, 72% of the patients were free from arrythmias.

CONCLUSIONS:

Persistent AF ablation is feasible without a CMC, reducing the need for venous and transseptal punctures and the cost of the procedure. We suggest that prospective studies should aim to characterise the reduction in procedure and fluoroscopy times as a result of this technique.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Ablación por Catéter Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Acta Cardiol Año: 2024 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Atrial / Ablación por Catéter Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Acta Cardiol Año: 2024 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido