Your browser doesn't support javascript.
loading
Visual performance and patient preference with bilateral implantation of an extended depth of focus or combined implantation of an extended depth of focus/trifocal intraocular lens.
Moore, Jonathan; Østergaard, Jens; Kretz, Florian.
Afiliación
  • Moore J; Cathedral Eye Clinic, Belfast, Northern Ireland.
  • Østergaard J; Hellerup Eye Clinic, Copenhagen, Denmark.
  • Kretz F; Augentagesklinik Rheine, Osnabrücker Straße 233 -235, 48429, Rheine, Germany. F.Kretz@precisevision.de.
Int Ophthalmol ; 44(1): 80, 2024 Feb 14.
Article en En | MEDLINE | ID: mdl-38356027
ABSTRACT

PURPOSE:

Evaluate postoperative visual performance in patients with bilaterally implanted AT LARA or AT LARA/AT LISA tri (Carl Zeiss AG, Jena, Germany) intraocular lenses.

METHODS:

Multicentered, comparative, open-label, retrospective/prospective study. Post-IOL implantation, patients were prospectively enrolled into this study; preoperative patient data were collected retrospectively. Follow-up was at 2-4 and 5-8 months post-surgery. The primary endpoint was binocular best corrected distance visual acuity (CDVA). The study was retrospectively registered on clinicaltrials.gov (#NCT05462067).

RESULTS:

Seventy-one patients (142 eyes) were enrolled; 67 patients (134 eyes) have 5-8 months data. The mean binocular CDVA at 2-4 months was -0.10 ± 0.06 logMAR in the bilateral AT LARA group ("bilateral") and -0.11 ± 0.09 logMAR in the combined implantation AT LARA/ AT LISA tri group ("combined implantation"); (P = 0.4856). At 5-8 months, mean binocular CDVA was -0.13 ± 0.06 logMAR in the bilateral group and -0.11 ± 0.09 in the combined implantation group (P = 0.4003). At 5-8 months, more eyes in the bilateral group attained 0.2 logMAR or better binocular uncorrected intermediate VA (UIVA; 67 cm) than those in the combined implantation group (100% vs. 94%, respectively). The bilateral group achieved a mean of 0.24 ± 0.11 logMAR in uncorrected near VA (UCNVA), compared to a mean of 0.16 ± 0.12 logMAR in the combined implantation group at 5-8 months (P = 0.0041).

CONCLUSIONS:

A combined implantation approach (AT LARA in the distance dominant eye/AT LISA tri in the non-dominant eye) produced similar CDVA outcomes but better UCNVA as bilateral implantation with the AT LARA. UIVA was comparable between groups. No new safety concerns were reported.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Int Ophthalmol Año: 2024 Tipo del documento: Article Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Facoemulsificación / Lentes Intraoculares Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Int Ophthalmol Año: 2024 Tipo del documento: Article Pais de publicación: Países Bajos