Determination of [Glu1]-fibrinopeptide B purity by gas chromatography - isotope dilution mass spectrometry.
Zhou, Dongmei; Wang, Xianxia; Zou, Jun; Song, Jiayi; Su, Ping; Yang, Yi; Wu, Liqing.
Afiliación
  • Zhou D; National Institute of Metrology, P.R. China, No. 18, North Third Ring East Road, Beijing, China. wulq@nim.ac.cn.
  • Wang X; National Institute of Metrology, P.R. China, No. 18, North Third Ring East Road, Beijing, China. wulq@nim.ac.cn.
  • Zou J; China Quality Certification Centre, Building 3, Zone 9, No. 188, South Fourth Ring West Road, Fengtai District, Beijing, China. doraabao@outlook.com.
  • Song J; Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing, China. jiayisongpro@163.com.
  • Su P; Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing, China. jiayisongpro@163.com.
  • Yang Y; Beijing University of Chemical Technology, North Third Ring Road 15, Chaoyang District, Beijing, China. jiayisongpro@163.com.
  • Wu L; National Institute of Metrology, P.R. China, No. 18, North Third Ring East Road, Beijing, China. wulq@nim.ac.cn.
Anal Methods ; 16(12): 1741-1747, 2024 Mar 22.
Article en En | MEDLINE | ID: mdl-38372017
ABSTRACT
The present work assessed the purity of [Glu1]-fibrinopeptide B (GFB) as a model peptide using gas chromatography - isotope dilution mass spectrometry. GFB and various isotope-labeled amino acids were hydrolyzed in HCl and then derivatized using optimized procedures. The primary impurity in GFB was also identified and used to correct the final result. A method repeatability of 0.5% was achieved and linear calibrations were obtained for five amino acids. The LOD and LOQ were 0.041 to 0.096 µg g-1, and 0.16 to 0.56 µg g-1, respectively. The purity of GFB was found to be (0.715 ± 0.012) g g-1. This technique exhibited comparable accuracy to that obtainable from liquid chromatography - isotope dilution mass spectrometry but at lower cost. This method could be employed as a reference technique or in fields such as clinical diagnostics or bio-pharmaceutical peptide purity analysis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Péptidos / Fibrinopéptido B Idioma: En Revista: Anal Methods Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Péptidos / Fibrinopéptido B Idioma: En Revista: Anal Methods Año: 2024 Tipo del documento: Article País de afiliación: China