Your browser doesn't support javascript.
loading
Flow arrest during carotid artery stenting with a distal embolic protection device: A single-center experience and clinical implications.
Hong, Noah; Park, Jeong-Mee; Kim, Seung Bin; Son, Young-Je.
Afiliación
  • Hong N; Department of Neurosurgery, Seoul National University-Seoul Metropolitan Government Boramae Medical Center, Seoul, Korea.
  • Park JM; Department of Neurosurgery, Seoul National University-Seoul Metropolitan Government Boramae Medical Center, Seoul, Korea.
  • Kim SB; Department of Critical Care Medicine, Seoul National University-Seoul Metropolitan Government Boramae Medical Center, Seoul, Korea.
  • Son YJ; Department of Neurosurgery, Seoul National University-Seoul Metropolitan Government Boramae Medical Center, Seoul, Korea.
J Cerebrovasc Endovasc Neurosurg ; 26(2): 163-173, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38403575
ABSTRACT

OBJECTIVE:

We aimed to investigate the incidence of flow arrest during carotid artery stenting (CAS) with filter-type embolic protection device (EPD), identify any predisposing factors for those situations, and contemplate intraprocedural precautionary steps.

METHODS:

CAS was performed in 128 patients with 132 arteries using filter-type EPD. The characteristics of treated patients and arteries were compared between groups with and without flow arrest.

RESULTS:

The incidence of flow arrest during CAS with filter-type EPD was 17.4%. In flow arrest group, cases of vulnerable plaques (p=0.02) and symptomatic lesions (p=0.01) were significantly more common, and there were more cases of debris captured by EPD in a planar pattern (p<0.01). Vulnerable plaques were significantly more common in the procedures showing a planar pattern than in the cases with other patterns (p<0.01). Flow arrest group showed a significantly higher rate of ischemic complications (p<0.05), although there were no significant periprocedural neurological changes. The planar pattern of captured debris in filter-type EPD was the only significant risk factor for flow arrest (adjusted odds ratio 88.44, 95% confidence interval 15.21-514.45, p<0.05).

CONCLUSIONS:

Flow arrest during CAS with filter-type EPD is not uncommon and associated with increased ischemic complications. Symptomatic stenoses and vulnerable plaque are related to this event. The planar pattern of captured debris on the EPD was the only significant risk factor for the flow arrest. Clinicians must pay attention to the occurrence of flow arrest and react quickly when performing CAS.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Cerebrovasc Endovasc Neurosurg Año: 2024 Tipo del documento: Article Pais de publicación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Cerebrovasc Endovasc Neurosurg Año: 2024 Tipo del documento: Article Pais de publicación: Corea del Sur