Your browser doesn't support javascript.
loading
Dual-Shaped Silver Nanoparticle Labels for Electrochemical Detection of Bioassays.
Pollok, Nicole E; Peng, Yi; Raj, Nikhil; Walgama, Charuksha; Crooks, Richard M.
Afiliación
  • Pollok NE; Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA.
  • Peng Y; Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA.
  • Raj N; Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA.
  • Walgama C; Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA.
  • Crooks RM; Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA.
ACS Appl Nano Mater ; 4(10): 10764-10770, 2021 Oct 22.
Article en En | MEDLINE | ID: mdl-38404358
ABSTRACT
In this paper we demonstrate the use of dual-shaped silver nanoparticles (AgNPs) as detection labels for electrochemical bioassays. The key finding is that by using AgNP labels having two different shapes simultaneously, the limit of detection (LOD) for the assays is lowered compared to using either of the two shapes separately. The two shapes were silver nanocubes (AgNCs) having edge lengths of 40 ± 4 nm and spherical AgNPs (sAgNPs) having diameters of 20 ± 3 nm. Two different bioassays were examined. In both cases the Ag labels were functionalized with antibodies. In the one assay, the labels are directly linked to a second antibody immobilized on magnetic beads. In the second assay, the antibodies on the AgNP labels and the antibodies on the magnetic beads are linked via a peptide. The peptide is N-terminal prohormone brain natriuretic peptide (NT-proBNP), which is a heart failure marker. The efficacy of the two electrochemical assays as a function of the ratio of the two labels was investigated using a galvanic exchange/anodic stripping voltammetry method. The key finding is that by optimizing the ratio of the two types of AgNP labels, it is possible to decrease the LOD of the assays without compromising the dynamic range compared to using either of the two labels independently. This made it possible to achieve the clinically relevant range for NT-proBNP analysis used by physicians for heart failure risk stratification.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Appl Nano Mater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ACS Appl Nano Mater Año: 2021 Tipo del documento: Article País de afiliación: Estados Unidos