Your browser doesn't support javascript.
loading
Mechanical stability of posterior implant-supported monolithic zirconia cantilever on titanium-base abutments. An in vitro study.
Riera, Carme; Karasan, Duygu; Sailer, Irena; Mojon, Phillipe; Fehmer, Vincent; Pitta, João.
Afiliación
  • Riera C; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Karasan D; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Sailer I; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Mojon P; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Fehmer V; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Pitta J; Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
Article en En | MEDLINE | ID: mdl-38415804
ABSTRACT

PURPOSE:

Investigate survival and technical complications of two-unit posterior implant-supported cantilever made of monolithic zirconia on titanium-base abutments (Zr-TiB) vs. porcelain-fused-to-metal on castable gold abutments (PFM-GA) using two different implant connections, internal butt-joint (IBJ) and internal conical (IC). MATERIALS AND

METHODS:

Forty-eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2-unit mandibular premolar cantilevers with two different materials (Zr-TiB vs. PFM-GA) and two connection types (IBJ vs. IC). Tested groups were as follows (1) IBJ/Zr-TiB; (2) IBJ/PFM-GA; (3) IC/Zr-TiB; and (4) IC/PFM-GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5-55°C) with occlusal axial load on the pontic. Catastrophic and non-catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated.

RESULTS:

From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM-GA) to 100% (IBJ/Zr-TiB; IBJ/PFM-GA; IC/Zr-TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB - 67%) compared to internal butt-joint (IBJ/Zr-TiB - 44%; IBJ/PFM-GA - 46%) (p < .01). Bending moments were higher in internal butt-joint connections than in internal conical (p < .05). CONCLUSION AND CLINICAL IMPLICATIONS Two-unit posterior implant-supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium-base abutments demonstrated higher mechanical stability compared to porcelain-fused-to-metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain-fused-to-metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.