Your browser doesn't support javascript.
loading
A GC×GC-MS method based on solid-state modulator for non-targeted metabolomics: Comparison with traditional GC-MS method.
Zhang, Yueyi; Ren, Haihui; Tang, Xiao; Liu, Qiaorong; Xiao, Wen; Zhang, Zunjian; Tian, Yuan.
Afiliación
  • Zhang Y; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China.
  • Ren H; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China.
  • Tang X; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China.
  • Liu Q; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China.
  • Xiao W; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China.
  • Zhang Z; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China; State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, PR China. Electronic address: zzj@cpu.edu.cn.
  • Tian Y; Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing 210009, PR China; State Key Laboratory of Natural Medicines, China Pharmaceutical University, Nanjing 210009, PR China. Electronic address: tiancpu@sina.com.
J Pharm Biomed Anal ; 243: 116068, 2024 Jun 15.
Article en En | MEDLINE | ID: mdl-38428247
ABSTRACT
The formidable challenge posed by the presence of extremely high amounts of compounds and large differences in concentrations in plasma significantly complicates non-targeted metabolomics analyses. In this study, a comprehensive two-dimensional gas chromatography-quadrupole mass spectrometry (GC×GC-qMS) method with a solid-state modulator (SSM) for non-targeted metabolomics in beagle plasma was first established based on a GC-MS method, and the qualitative and quantitative performance of the two platforms were compared. Identification of detected compounds was accomplished utilizing NIST database match scores, retention indices (RIs) and standards. Semi-quantification involved the calculation of peak area ratios to internal standards. Metabolite identification sheets were generated for plasma samples on both analytical platforms, featuring 22 representative metabolites chosen for validating qualitative accuracy, and for conducting comparisons of linearity, accuracy, precision, and sensitivity. The outcomes revealed a threefold increase in the number of identifiable metabolites on the GC×GC-MS platform, with lower limits of quantitation (LLOQs) reduced to 0.5-0.05 times those achieved on the GC-MS platform. Accuracy in quantification for both GC×GC-MS and GC-MS fell within the range of 85-115%, and the vast majority of intra- and inter-day precisions were within the range of 20%. These findings underscore that relative to the conventional GC-MS method, the GC×GC-MS method developed in this study, combined with SSM, exhibits enhanced qualitative capabilities, heightened sensitivity, and comparable accuracy and precision, rendering it more suitable for non-targeted metabolomics analyses.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Plasma / Metabolómica Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Plasma / Metabolómica Límite: Animals Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido