Your browser doesn't support javascript.
loading
Comparison of T-POD and SAM Pelvic Sling II and the influence of attachment level in the initial management of unstable pelvic type C injuries - a cadaveric study.
Privalov, Maxim; Junge, Malte; Jung, Matthias Karl; Vetter, Sven Yves; Franke, Jochen; Hetjens, Svetlana; Grützner, Paul Alfred; Stadthalter, Holger.
Afiliación
  • Privalov M; Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
  • Junge M; Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
  • Jung MK; Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
  • Vetter SY; Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
  • Franke J; Department for Trauma and Orthopaedic Surgery, Tauernklinikum, Paracelsusstraße 8, Zell am See, 5700, Austria.
  • Hetjens S; Department of Medical Statistics, Biomathematics and Data Processing, Universitätsklinikum Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
  • Grützner PA; Department for Trauma and Orthopaedic Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
  • Stadthalter H; Friedrich-Alexander-University Erlangen-Nürnberg, Krankenhaus-Str. 12, 91054, Erlangen, Germany. holger@stadthalter.at.
Int J Emerg Med ; 17(1): 34, 2024 Mar 04.
Article en En | MEDLINE | ID: mdl-38438968
ABSTRACT

BACKGROUND:

Type C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a crucial role in their initial management. Placement at the correct level in the prehospital setting is challenging. The aim of this study was to compare two pelvic binders regarding their effectiveness in reducing intrapelvic volume and increasing intrapelvic pressure in patients with type C pelvic fractures (AO/OTA) when applied at three different levels.

METHODS:

Rotationally and vertically unstable pelvic injuries (AO/OTA classification 61-C1.1) were produced in five fresh-frozen human cadaveric specimens. Intrapelvic volume, vesical pressure and compression pressure within the pubic symphysis and the sacroiliac joint were measured when applying a SAM Pelvic Sling II and a T-POD at the level of the greater trochanter as well as levels higher and lower than recommended.

RESULTS:

Comparison of the two pelvic binders positioned at the recommended level (greater trochanter) showed no significant difference in volume reduction (13.85 ± 31.37 cm3, p = 0.442), however, increase in vesical pressure was significantly higher when using the T-POD (5.80 ± 3.27 cmH2O, p = 0.017). When positioned at the level of the iliac crest, vesical pressure increase and intrapelvic volume reduction were significantly greater with the T-POD (14.00 ± 8.57 cmH2O, p = 0.022 and 10.45 ± 5.45 cm3, p = 0.031 respectively). Application of the SAM Pelvic Sling II below the greater trochanter led to a significantly greater decrease in volume (-32.26 ± 7.52 cm3, p = 0.003) than the T-POD. Comparison of the recommended attachment level with incorrect positioning led to no significant differences for the T-POD, while the SAM Pelvic Sling II achieved a significantly lower volume reduction when placed at the iliac crest (40.15 ± 14.57 cm3, p = 0.012) and a significantly lower increase in vesical pressure when applied below the greater trochanter (3.40 ± 1.52 cmH2O, p = 0.007).

CONCLUSION:

Direct comparison of the two pelvic binders showed that the T-POD achieved significantly greater results when applied at the recommended level and was less susceptible to incorrect positioning. These outcomes support the preferred use of the T-POD for prehospital emergency pelvic stabilisation.