Your browser doesn't support javascript.
loading
Transient X-Ray Absorption Near Edge Structure Spectroscopy Using Broadband Free-Electron Laser Pulses.
Juranic, Pavle; Cirelli, Claudio; Mamyrbayev, Talgat; Uemura, Yohei; Vila-Comamala, Joan; Lima, Frederico Alves; Bacellar, Camila; Johnson, Philip J M; Prat, Eduard; Reiche, Sven; Wach, Anna; Bykova, Iuliia; Kahraman, Abdullah; Kabanova, Victoria; Milne, Christopher; David, Christian.
Afiliación
  • Juranic P; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Cirelli C; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Mamyrbayev T; XRnanotech GmbH, PSI, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Uemura Y; European XFEL GmbH, Holzkoppel 4, 22869, Schenefeld, Germany.
  • Vila-Comamala J; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Lima FA; European XFEL GmbH, Holzkoppel 4, 22869, Schenefeld, Germany.
  • Bacellar C; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Johnson PJM; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Prat E; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Reiche S; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Wach A; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Bykova I; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Kahraman A; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Kabanova V; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
  • Milne C; European XFEL GmbH, Holzkoppel 4, 22869, Schenefeld, Germany.
  • David C; Paul Scherrer Institute, Forschungsstrasse 111, Villigen, 5232, Switzerland.
Small Methods ; 8(8): e2301328, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38441281
ABSTRACT
A new method for time-resolved X-ray absorption near edge structure (XANES) spectroscopy that enables faster data acquisition and requires smaller sample quantities for high-quality data, thus allowing the analysis of more samples in a shorter time is introduced. The method uses large bandwidth free electron laser pulses to measure laser-excited XANES spectra in transmission mode. A beam-splitting grating configuration allows simultaneous measurements of the spectra of the incoming X-ray Free Electron Laser (XFEL) pulses and transmission XANES, which is crucial for compensating the pulse-dependent intensity and spectrum fluctuations due to the self-amplified spontaneous emission operation. The implementation of this new methodology is applied on a liquid solution of ammonium iron(III) oxalate jet and is compared to previous results, showing great improvements in the speed of acquisition and spectral resolution, and the ability to measure a large 2-D spectral-time map quickly.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Small Methods Año: 2024 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Small Methods Año: 2024 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Alemania