Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography.
Eur Heart J Cardiovasc Imaging
; 25(7): 996-1006, 2024 Jun 28.
Article
en En
| MEDLINE
| ID: mdl-38445511
ABSTRACT
AIMS:
Variation in diagnostic performance of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD) and its interaction with age and sex. METHODS ANDRESULTS:
A total of 2066 patients without known CAD (67% male, 64.7 ± 11.2 years) across nine institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated the performance of quantitative and visual assessments according to cardiac size [end-diastolic volume (EDV); <20th vs. ≥20th population or sex-specific percentiles], age (<75 vs. ≥75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared with those without (AUC population 0.72 vs. 0.78, P = 0.03; sex-specific 0.72 vs. 0.79, P = 0.01) and elderly patients compared with younger patients (AUC 0.72 vs. 0.78, P = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, P = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold EDV 0.69 vs. 0.79, P = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex.CONCLUSION:
Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Enfermedad de la Arteria Coronaria
/
Tomografía Computarizada de Emisión de Fotón Único
/
Sistema de Registros
/
Imagen de Perfusión Miocárdica
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Eur Heart J Cardiovasc Imaging
Año:
2024
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Reino Unido