Your browser doesn't support javascript.
loading
Novel nickel(II) phthalocyanine/reduced graphene oxide: an electrochemical sensing platform for analysis of hydroquinone and chloramphenicol in environmental samples.
Manikanta, P; Nikam, Rohit Rangnath; Tigari, Girish; Nagaraja, Bhari Mallanna.
Afiliación
  • Mounesh; Centre for Nano and Material Science (CNMS), Jain (Deemed-to-be University), Jain Global Campus, Kanakapura, Bangalore, Karnataka, 562112, India. mounesh.m.nayak@gmail.com.
  • Manikanta P; Centre for Nano and Material Science (CNMS), Jain (Deemed-to-be University), Jain Global Campus, Kanakapura, Bangalore, Karnataka, 562112, India. mounesh.m.nayak@gmail.com.
  • Nikam RR; Centre for Nano and Material Science (CNMS), Jain (Deemed-to-be University), Jain Global Campus, Kanakapura, Bangalore, Karnataka, 562112, India. mounesh.m.nayak@gmail.com.
  • Tigari G; Department of Chemistry, Nitte Meenakshi Institute of Technology, Yelahanka, Bangalore 560064, Karnataka, India.
  • Nagaraja BM; Centre for Nano and Material Science (CNMS), Jain (Deemed-to-be University), Jain Global Campus, Kanakapura, Bangalore, Karnataka, 562112, India. mounesh.m.nayak@gmail.com.
Anal Methods ; 16(12): 1770-1784, 2024 Mar 22.
Article en En | MEDLINE | ID: mdl-38456643
ABSTRACT
Novel tetra-2-(biphenyl-4-yl)-1,3-benzoxazol-carboxamide nickel(II) phthalocyanine (NiTBPBXCAPc) and rGO were confirmed using FT-IR, UV-vis, XRD, TGA and Raman spectra. The NiTBPBXCAPc and rGO nanocomposite has been developed to detect hydroquinone (HQN) and chloramphenicol (CPC). NiTBPBXCAPc has been examined using cyclic voltammetry (CV), linear sweep voltammetry (LSV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) analysis. The simultaneous CV analysis of HQN and CPC demonstrated the ability of NiTBPBXCAPc@rGO/GCE to execute simultaneous redox reactions. The voltammetric and amperometric limit of detection for HQN and CPC was determined to be 4.5 and 3.5 nM respectively, with a sensitivity of 0.446 and 0.416 µA M-1 cm-2. The amperometric LOD was observed to be 5 and 4 nM with a sensitivity of 0.235 and 0.288 µA M-1 cm-2. Additionally, the NiTBPBXCAPc@rGO/GC electrode is also used for real sample analysis with outstanding recovery. The long-term storage stability, reusability, and real-world sample analysis of the NiTBPBXCAPc@rGO/GC electrode demonstrated its use in environmental analysis.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Methods / Analytical methods (Online) Año: 2024 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Anal Methods / Analytical methods (Online) Año: 2024 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido