Your browser doesn't support javascript.
loading
A disposable paper-based electrochemical biosensor decorated by electrospun cellulose acetate nanofibers for highly sensitive bio-detection.
Zhang, Zhiwei; Du, Manman; Cheng, Xiao; Dou, Xuechen; Zhou, Junting; Wu, Jianguo; Xie, Xinwu; Zhu, Mengfu.
Afiliación
  • Zhang Z; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
  • Du M; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
  • Cheng X; School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China.
  • Dou X; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
  • Zhou J; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
  • Wu J; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
  • Xie X; School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin 300222, China.
  • Zhu M; Systems Engineering Institute, People's Liberation Army, Tianjin 300161, China. xinwuxie@163.com.
Analyst ; 149(8): 2436-2444, 2024 Apr 15.
Article en En | MEDLINE | ID: mdl-38498083
ABSTRACT
Paper-based electrochemical sensors have the characteristics of flexibility, biocompatibility, environmental protection, low cost, wide availability, and hydropathy, which make them very suitable for the development and application of biological detection. This work proposes electrospun cellulose acetate nanofiber (CA NF)-decorated paper-based screen-printed (PBSP) electrode electrochemical sensors. The CA NFs were directly collected on the PBSP electrode through an electrospinning technique at an optimized voltage of 16 kV for 10 min. The sensor was functionalized with different bio-sensitive materials for detecting different targets, and its sensing capability was evaluated by CV, DPV, and chronoamperometry methods. The test results demonstrated that the CA NFs enhanced the detection sensitivity of the PBSP electrode, and the sensor showed good stability, repeatability, and specificity (p < 0.01, N = 3). The electrochemical sensing of the CA NF-decorated PBSP electrode exhibited a short detection duration of ∼5-7 min and detection ranges of 1 nmol mL-1-100 µmol mL-1, 100 fg mL-1-10 µg mL-1, and 1.5 × 102-106 CFU mL-1 and limits of detection of 0.71 nmol mL-1, 89.1 fg mL-1, and 30 CFU mL-1 for glucose, Ag85B protein, and E. coli O157H7, respectively. These CA NF-decorated PBSP sensors can be used as a general electrochemical tool to detect, for example, organic substances, proteins, and bacteria, which are expected to achieve point-of-care testing of pathogenic microorganisms and have wide application prospects in biomedicine, clinical diagnosis, environmental monitoring, and food safety.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Celulosa / Escherichia coli O157 / Nanofibras Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Celulosa / Escherichia coli O157 / Nanofibras Idioma: En Revista: Analyst Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM