Your browser doesn't support javascript.
loading
Ultrasensitive detection of zearalenone based on electrochemiluminescent immunoassay with Zr-MOF nanoplates and Au@MoS2 nanoflowers.
Peng, Lu; Qian, Xinyue; Jin, Ya; Miao, Xiangyang; Deng, Anping; Li, Jianguo.
Afiliación
  • Peng L; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, PR China.
  • Qian X; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, PR China.
  • Jin Y; Department of Biomedical and Pharmaceutical Sicences, Suzhou Chien-shiung Institute of Technology, Taicang, 215411, PR China.
  • Miao X; Department of Biomedical and Pharmaceutical Sicences, Suzhou Chien-shiung Institute of Technology, Taicang, 215411, PR China. Electronic address: jsnjxiazi@163.com.
  • Deng A; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, PR China. Electronic address: denganping@suda.edu.cn.
  • Li J; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, PR China. Electronic address: lijgsd@suda.edu.cn.
Anal Chim Acta ; 1299: 342451, 2024 Apr 22.
Article en En | MEDLINE | ID: mdl-38499431
ABSTRACT
In this work, an effective competitive-type electrochemiluminescence (ECL) immunosensor was constructed for zearalenone determination by using Zr-MOF nanoplates as the ECL luminophore and Au@MoS2 nanoflowers as the substrate material. Zr-MOF have an ultra-thin sheet-like structure that accelerates the transfer of electrons, ions and co-reactant intermediates, which exhibited strong and stable anodic luminescence. The three-dimensional Au@MoS2 nanoflowers would form a thin film modification layer on the glassy carbon electrode (GCE). And its good electrical conductivity and higher specific surface area utilization further improving the sensitivity of the ECL immunosensor. Under the optimized conditions, the proposed immunosensor exhibited satisfactory stability, sensitivity and accuracy, and its ECL signal was proportional to the logarithm of ZEN concentration (0.0001-100 ng/mL) and the limit of detection (LOD) was 0.034 pg/mL. In addition, the results of recovery experiment acquired for wheat flour and pig urine samples further proved the feasibility of the immunosensor for the detection of real samples, indicating its potential for ultrasensitive detection of ZEN.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Zearalenona / Técnicas Biosensibles / Nanopartículas del Metal Límite: Animals Idioma: En Revista: Anal Chim Acta Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Zearalenona / Técnicas Biosensibles / Nanopartículas del Metal Límite: Animals Idioma: En Revista: Anal Chim Acta Año: 2024 Tipo del documento: Article