Your browser doesn't support javascript.
loading
Fabrication of a novel HKUST-1/CoFe2O4/g-C3N4 electrode for the electrochemical detection of ciprofloxacin in physiological samples.
Liu, Rui; Zhang, Chaojun; Wu, Tianheng; Liu, Rijia; Sun, Yuan; Ma, Jing.
Afiliación
  • Liu R; Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China. Electronic address: liur@hrbcu.edu.cn.
  • Zhang C; Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China.
  • Wu T; Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China.
  • Liu R; Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China.
  • Sun Y; Center of Pharmaceutical Engineering and Technology, Harbin University of Commerce, Harbin, 150076, China. Electronic address: sunyuan.2010@163.com.
  • Ma J; Department of Chemical Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China. Electronic address: majing@xauat.edu.cn.
Talanta ; 273: 125882, 2024 Jun 01.
Article en En | MEDLINE | ID: mdl-38513472
ABSTRACT
In this work, a novel HKUST-1/CoFe2O4/g-C3N4 electrode was successfully prepared via the hydrothermal method and the high-temperature calcination method, which can be applied as an electrochemical sensor for the precise detection of ciprofloxacin (CIP) in physiological samples. The novel electrode was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FT-IR), and its electrochemical performance was further evaluated via the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The results demonstrated that the HKUST-1/CoFe2O4/g-C3N4 electrode exhibited an optimal linear range of 0.05-180 µmol L-1 for the CIP detection, which demonstrated a low limit of detection (LOD) of 0.0026 µmol L-1 and a low limit of quantitation (LOQ) of 0.0087 µmol L-1, respectively. Additionally, the novel semiconductor sensors exhibited exceptional selectivity, stability and repeatability in the determination of CIP. The recovery rate of CIP was found to range from 98.00% to 104.00% in serum, with the relative standard deviations (RSD) below 2.62% (n = 5), while the recovery rate of CIP was found to range from 96.00% to 105.00%, with the RSD less than 3.23% (n = 5) in urine. The current study extends to the application of the semiconductor-based electrochemical sensors and offers a new approach for the clinical pharmaceutical analysis to ensure medication safety, which could provide valuable insights into the potential of semiconductor sensors for future clinical applications.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estructuras Metalorgánicas Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article Pais de publicación: Países Bajos