Your browser doesn't support javascript.
loading
The development, evaluation, performance, and validation of micro-PCR and extractor for the quantification of HIV-1 &-2 RNA.
Prakash, Shyam; Aasarey, Ram; Sharma, Meenakshi; Khan, Shahid.
Afiliación
  • Prakash S; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India. prakashaiims@gmail.com.
  • Aasarey R; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India.
  • Priyatma; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India.
  • Sharma M; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India.
  • Khan S; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India.
  • Medha; Department of Laboratory Medicine, All India Institute of Medical Sciences, Room No 11, 2nd Floor, Ansari Nagar, New Delhi, 110029, India.
Sci Rep ; 14(1): 8700, 2024 04 15.
Article en En | MEDLINE | ID: mdl-38622191
ABSTRACT
HIV infection has been a global public health threat and overall reported ~ 40 million deaths. Acquired immunodeficiency syndrome (AIDS) is attributed to the retroviruses (HIV-1/2), disseminated through various body fluids. The temporal progression of AIDS is in context to the rate of HIV-1 infection, which is twice as protracted in HIV-2 transmission. Q-PCR is the only available method that requires a well-developed lab infrastructure and trained personnel. Micro-PCR, a portable Q-PCR device, was developed by Bigtec Labs, Bangalore, India. It is simple, accurate, fast, and operationalised in remote places where diagnostic services are inaccessible in developing countries. This novel micro-PCR determines HIV-1 and HIV-2 viral load using a TruePrep™ extractor device for RNA isolation. Five ml blood samples were collected at the blood collection centre at AIIMS, New Delhi, India. Samples were screened for serology, and a comparison of HIV-1/2 RNA was done between qPCR and micro-PCR in the samples. The micro-PCR assay of HIV-RNA has compared well with those from real-time PCR (r = 0.99, i < 0.002). Micro-PCR has good inter and intra-assay reproducibility over a wide dynamic range (1.0 × 102-1.0 × 108 IU/ml). The linear dynamic range was 102-108 IU/ml. The clinical and analytical specificity of the assay was comparable, i.e., 100%. Intra-assay and inter-assay coefficients of variation ranged from 1.17% to 3.15% and from 0.02% to 0.46%, respectively. Moreover, due to the robust, simple, and empirical method, the Probit analysis has also been done for qPCR LODs to avoid uncertainties in target recoveries. The micro-PCR is reliable, accurate, and reproducible for early detection of HIV-1 and HIV-2 viral loads simultaneously. Thus, it can easily be used in the field and in remote places where quantification of both HIV-1/2 is not reachable.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / Síndrome de Inmunodeficiencia Adquirida / VIH-1 / Seropositividad para VIH Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / Síndrome de Inmunodeficiencia Adquirida / VIH-1 / Seropositividad para VIH Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido