Your browser doesn't support javascript.
loading
Higher contact pressure of the lateral tibiofemoral joint in lateral extra-articular tenodesis with tensioned graft in external rotation than in neutral rotation: A biomechanical study.
Itthipanichpong, Thun; Limskul, Danaithep; Tanpowpong, Thanathep; Virulsri, Chanyaphan; Tangpornprasert, Pairat; Kuptniratsaikul, Somsak; Thamrongskulsiri, Napatpong.
Afiliación
  • Itthipanichpong T; Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand.
  • Limskul D; Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand.
  • Tanpowpong T; Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand.
  • Virulsri C; Center of Excellence for Prosthetic and Orthopedic Implant, Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand.
  • Tangpornprasert P; Center of Excellence for Prosthetic and Orthopedic Implant, Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand.
  • Kuptniratsaikul S; Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand.
  • Thamrongskulsiri N; Department of Anatomy, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand. Electronic address: napatpong.tha@gmail.com.
J ISAKOS ; 2024 Apr 16.
Article en En | MEDLINE | ID: mdl-38636904
ABSTRACT

OBJECTIVE:

To determine the mean contact pressure, peak contact pressure, and mean contact area of the lateral tibiofemoral joint in lateral extra-articular tenodesis (LET) with tension on the graft in tibial neutral and external rotation.

METHODS:

A total of eight Thiel-embalmed cadaveric knees were prepared and divided into two groups (4 knees in each group) the LET-NR group (lateral extra-articular tenodesis tension in neutral rotation) and (2) the LET-ER group (lateral extra-articular tenodesis tension in external rotation). Each knee was prepared according to the corresponding technique. A hydraulic testing system (E10000, Instron) simulates an axial load of 735 â€‹N for 10 â€‹s in each group.

RESULTS:

The LET-ER group exhibited a statistically significant higher peak contact pressure compared to the LET-NR group. The peak contact pressure values in the LET-NR and LET-ER groups were 702.3 â€‹± â€‹233.9 â€‹kPa and 1235.5 â€‹± â€‹171.4 â€‹kPa, respectively (p â€‹= â€‹0.010, 95% CI, -888.0 to -178.5). The mean contact pressure values in the LET-NR and LET-ER groups were 344.9 â€‹± â€‹69.0 â€‹kPa and 355.3 â€‹± â€‹34.9 â€‹kPa, respectively (p â€‹= â€‹0.796, 95% CI, -105.1-84.2). The mean contact area values in the LET-NR and LET-ER groups were 36.8 â€‹± â€‹3.1 mm2 and 33.3 â€‹± â€‹6.4 mm2, respectively (p â€‹= â€‹0.360, 95% CI, -5.2-12.2).

CONCLUSIONS:

The peak contact pressure of the lateral tibiofemoral joint is greater in LET when the graft is tensioned in external rotation than in neutral rotation. However, no statistically significant difference in the mean contact pressure or the mean contact area was observed between the two groups. LEVEL OF EVIDENCE III.
Palabras clave