Planar dose calculation of electron therapy.
Gebreamlak, Wondesen T; Alkhatib, Hassaan H.
Afiliación
  • Gebreamlak WT; South Carolina Oncology Associates, Columbia, SC 29210, United States of America.
  • Alkhatib HH; South Carolina Oncology Associates, Columbia, SC 29210, United States of America.
Biomed Phys Eng Express ; 10(4)2024 May 14.
Article en En | MEDLINE | ID: mdl-38688251
ABSTRACT
Purpose.The aim of this study is to determine the planar dose distribution of irregularly-shaped electron beams at their maximum dose depth (zmax) using the modied lateral build-up ratio (LBR) and curve-fitting methods.Methods.Circular and irregular cutouts were created using Cerrobend alloy for a 14 × 14 cm2applicator. Percentage depth dose (PDD) at the standard source-surface-distance (SSD = 100 cm) and point dose at different SSD were measured for each cutout. Orthogonal profiles of the cutouts were measured atzmax. Data were collected for 6, 9, 12, and 15 MeV electron beam energies on a VERSA HDTMLINAC using the IBA Blue Phantom23D water phantom system. The planar dose distributions of the cutouts were also measured atzmaxin solid water using EDR2 films.Results.The measured PDD curves were normalized to a normalization depth (d0) of 1 mm. The lateral-buildup-ratio (LBR), lateral spread parameter (σR(z)), and effective SSD (SSDeff) for each cutout were calculated using the PDD of the open applicator as the reference field. The modified LBR method was then employed to calculate the planar dose distribution of the irregular cutouts within the field at least 5 mm from the edge. A simple curve-fitting model was developed based on the profile shapes of the circular cutouts around the field edge. This model was used to calculate the planar dose distribution of the irregular cutouts in the region from 3 mm outside to 5 mm inside the field edge. Finally, the calculated planar dose distribution was compared with the film measurement.Conclusions.The planar dose distribution of electron therapy for irregular cutouts atzmaxwas calculated using the improved LBR method and a simple curve-fitting model. The calculated profiles were within 3% of the measured values. The gamma passing rate with a 3%/3 mm and 10% dose threshold was more than 96%.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Dosificación Radioterapéutica / Fantasmas de Imagen / Electrones Límite: Humans Idioma: En Revista: Biomed Phys Eng Express Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Dosificación Radioterapéutica / Fantasmas de Imagen / Electrones Límite: Humans Idioma: En Revista: Biomed Phys Eng Express Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido