Your browser doesn't support javascript.
loading
Improving material properties of a poloxamer P407 hydrogel-based hydroxyapatite bone substitute material by adding silica-A comparative in vivo study.
Kämmerer, Peer W; Heimes, Diana; Zaage, Franziska; Ganz, Cornelia; Frerich, Bernhard; Gerber, Thomas; Dau, Michael.
Afiliación
  • Kämmerer PW; Department of Oral, Maxillofacial Plastic Surgery, University Medical Center Mainz, Mainz, Germany.
  • Heimes D; Department of Oral, Maxillofacial Plastic Surgery, University Medical Center Rostock, Rostock, Germany.
  • Zaage F; Department of Oral, Maxillofacial Plastic Surgery, University Medical Center Mainz, Mainz, Germany.
  • Ganz C; Institute of Physics, Rostock University, Rostock, Germany.
  • Frerich B; Institute of Physics, Rostock University, Rostock, Germany.
  • Gerber T; Department of Oral, Maxillofacial Plastic Surgery, University Medical Center Rostock, Rostock, Germany.
  • Dau M; Institute of Physics, Rostock University, Rostock, Germany.
J Biomed Mater Res B Appl Biomater ; 112(5): e35405, 2024 May.
Article en En | MEDLINE | ID: mdl-38701384
ABSTRACT
The structure and handling properties of a P407 hydrogel-based bone substitute material (BSM) might be affected by different poloxamer P407 and silicon dioxide (SiO2) concentrations. The study aimed to compare the mechanical properties and biological parameters (bone remodeling, BSM degradation) of a hydroxyapatite silica (HA)-based BSM with various P407 hydrogels in vitro and in an in vivo rat model. Rheological analyses for mechanical properties were performed on one BSM with an SiO2-enriched hydrogel (SPH25) as well on two BSMs with unaltered hydrogels in different gel concentrations (PH25 and PH30). Furthermore, the solubility of all BSMs were tested. In addition, 30 male Wistar rats underwent surgical creation of a well-defined bone defect in the tibia. Defects were filled randomly with PH30 (n = 15) or SPH25 (n = 15). Animals were sacrificed after 12 (n = 5 each), 21 (n = 5 each), and 63 days (n = 5 each). Histological evaluation and histomorphometrical quantification of new bone formation (NB;%), residual BSM (rBSM;%), and soft tissue (ST;%) was conducted. Rheological tests showed an increased viscosity and lower solubility of SPH when compared with the other hydrogels. Histomorphometric analyses in cancellous bone showed a decrease of ST in PH30 (p = .003) and an increase of NB (PH30 p = .001; SPH p = .014) over time. A comparison of both BSMs revealed no significant differences. The addition of SiO2 to a P407 hydrogel-based hydroxyapatite BSM improves its mechanical stability (viscosity, solubility) while showing similar in vivo healing properties compared to PH30. Additionally, the SiO2-enrichment allows a reduction of poloxamer ratio in the hydrogel without impairing the material properties.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ratas Wistar / Durapatita / Dióxido de Silicio / Sustitutos de Huesos / Poloxámero / Hidrogeles Límite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ratas Wistar / Durapatita / Dióxido de Silicio / Sustitutos de Huesos / Poloxámero / Hidrogeles Límite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Alemania