An uncommon case of a bladder injury due to hip prosthesis migration: A case report.
Urol Case Rep
; 54: 102743, 2024 May.
Article
en En
| MEDLINE
| ID: mdl-38706875
ABSTRACT
Bladder injuries, although rare, can occur as a complication of hip surgery, particularly when a hip prosthesis migrates into the bladder. We present the case of a 75-year-old woman with a bladder rupture secondary to prosthesis migration requiring repair via a transvesical approach. While total hip arthroplasty (THA) is common, intrapelvic complications such as bladder injury are less commonly reported. Early recognition and appropriate treatment are essential to avoid serious consequences. The management of prosthesis migration into the bladder is complex and requires detailed anatomical knowledge. Awareness of this potential complication is essential for both orthopaedic surgeons and urologists.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Idioma:
En
Revista:
Urol Case Rep
Año:
2024
Tipo del documento:
Article
País de afiliación:
Marruecos
Pais de publicación:
Estados Unidos