Investigation of the precision of a novel jaw tracking system in recording mandibular movements: A preliminary clinical study.
Grande, Francesco; Lepidi, Luca; Tesini, Fabio; Acquadro, Alessio; Valenti, Chiara; Pagano, Stefano; Catapano, Santo.
Afiliación
  • Grande F; PhD student at Politecnico of Turin, Turin Italy; University of Ferrara, Ferrara Italy. Electronic address: Francesco.grande@polito.it.
  • Lepidi L; Adjunct Professor Gnathology, University of Ferrara, Ferrara Italy.
  • Tesini F; University of Ferrara, Ferrara Italy. Electronic address: Tsnfba@unife.it.
  • Acquadro A; University of Ferrara, Ferrara Italy.
  • Valenti C; PhD student at University of Padua, Padua Italy.
  • Pagano S; Chief-Professor Dental Materials, Oral Prosthodontic, University of Perugia, Perugia, Italy.
  • Catapano S; Chief-Professor Dental Materials, Oral Prosthodontic, University of Ferrara, Ferrara, Italy.
J Dent ; 146: 105047, 2024 07.
Article en En | MEDLINE | ID: mdl-38719134
ABSTRACT

OBJECTIVES:

This preliminary study aimed to clinically assess the precision of a novel optical jaw tracking system (JTS) in registering mandibular movements (MMs) of protrusion and mediotrusion.

METHODS:

Twenty healthy participants underwent recordings using Cyclops JTS (Itaka Way Med) for functional MMs of protrusion and laterotrusion by two trained clinicians. Each subject performed five registrations at different times according to a standardized pattern within one-month period. The angulations of protrusive and mediotrusive functional paths within the first 2 mm from the maximal intercuspal position (MIP) were calculated for each trace, using a data software for angle measurements. Descriptive statistics were used to assess the repeatability of the recordings for each participant and MM. Additionally, inferential statistics were carried out on standard deviation values obtained (α=0.05).

RESULTS:

The overall precision for all the patients was 7.07±3.37° for the protrusion angle, 5.24±2.24° for right laterotrusion and 5.14±3.06° for left laterotrusion angles. The protrusion angle ranged from 3.08° to 13.57°, while the right and left laterotrusion ranged from 1.82° to 9.42° and from 1.58° to 10.59°, respectively. No statistically significant differences were observed between different functional MM types and gender (p > 0.05).

CONCLUSIONS:

Recordings functional MMs of mediotrusion and protrusion using Cyclops JTS showed consistent repeatability, regardless of gender and functional MM type. The results revealed non-negligible variations that may be due to the patients' abilities to precisely reproduce jaw movements or to the operator's ability to consistently connect the kinesiograph. CLINICAL

SIGNIFICANCE:

Capturing functional MMs digitally and importing the data into dental CAD software is essential for virtual waxing in prosthetic rehabilitations to design a functionalized adapted occlusion. Establishing the repeatability of MM recordings by a JTS is a crucial step in better understanding this novel JTS in the market. This process could facilitate the interpretation of cusp angles, aid in CAD dynamic technical modeling, and enhance clinical data communication between clinicians and technicians in a modern workflow.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mandíbula / Movimiento Límite: Adult / Female / Humans / Male Idioma: En Revista: J Dent Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Mandíbula / Movimiento Límite: Adult / Female / Humans / Male Idioma: En Revista: J Dent Año: 2024 Tipo del documento: Article