Quantification of mechanical behavior of rat tail under compression.
Moore, Kevin D; Wu, John Z; Krajnak, Kristine; Warren, Christopher; Dong, Renguang G.
Afiliación
  • Moore KD; Physical Effects Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV, USA.
  • Wu JZ; Physical Effects Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV, USA.
  • Krajnak K; Physical Effects Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV, USA.
  • Warren C; Physical Effects Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV, USA.
  • Dong RG; Physical Effects Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Morgantown, WV, USA.
Biomed Mater Eng ; 35(4): 337-349, 2024.
Article en En | MEDLINE | ID: mdl-38758990
ABSTRACT
BACKGORUND The development of vibration-induced finger disorders is likely associated with combined static and dynamic responses of the fingers to vibration exposure. To study the mechanism of the disorders, a new rat-tail model has been established to mimic the finger vibration and pressure exposures. However, the mechanical behavior of the tail during compression needs to be better understood to improve the model and its applications.

OBJECTIVE:

To investigate the static and time-dependent force responses of the rat tail during compression.

METHODS:

Compression tests were conducted on Sprague-Dawley cadaver rat tails using a micromechanical system at three deformation velocities and three deformation magnitudes. Contact-width and the time-histories of force and deformation were measured. Additionally, force-relaxation tests were conducted and a Prony series was used to model the force-relaxation behavior of the tail.

RESULTS:

The rat tails' force-deformation and stiffness-deformation relationships were strongly nonlinear and time-dependent. Force/stiffness increased with an increase in deformation and deformation velocity. The time-dependent force-relaxation characteristics of the tails can be well described using a Prony series. CONCULSIONS We successfully quantified the static and time-dependent force responses of rat tails under compression. The identified mechanical behavior of the tail can help improve the rat-tail model and its applications.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Cola (estructura animal) / Ratas Sprague-Dawley / Fuerza Compresiva Límite: Animals Idioma: En Revista: Biomed Mater Eng Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Cola (estructura animal) / Ratas Sprague-Dawley / Fuerza Compresiva Límite: Animals Idioma: En Revista: Biomed Mater Eng Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Países Bajos