Passive Wireless Partial Discharge Sensors with Multiple Resonances.
Xu, Zhenheng; Tian, Bing; Guo, Shiqi; Huang, Qingan; Wang, Lifeng; Dong, Lei.
Afiliación
  • Xu Z; Key Laboratory of MEMS of the Ministry of Education, School of Electronic Science & Engineering, Southeast University, Nanjing 210096, China.
  • Tian B; CSG Sensing Technology (Guangdong) Co., Ltd., Shenzhen 518067, China.
  • Guo S; CSG Sensing Technology (Guangdong) Co., Ltd., Shenzhen 518067, China.
  • Huang Q; Key Laboratory of MEMS of the Ministry of Education, School of Electronic Science & Engineering, Southeast University, Nanjing 210096, China.
  • Wang L; Key Laboratory of MEMS of the Ministry of Education, School of Electronic Science & Engineering, Southeast University, Nanjing 210096, China.
  • Dong L; Key Laboratory of MEMS of the Ministry of Education, School of Electronic Science & Engineering, Southeast University, Nanjing 210096, China.
Micromachines (Basel) ; 15(5)2024 May 17.
Article en En | MEDLINE | ID: mdl-38793229
ABSTRACT
Partial discharge (PD) is the dominant insulating defect in Gas-Insulated Switchgear (GIS). The existing detection methods are mainly divided into built-in wire-connected disk antennas with destructive drilling and external ultra-high frequency antennas with poor anti-interference ability. This research introduces a passive wireless PD sensor implanted inside GIS on the observation window. The sensor is implemented by a sheeting branch-inductor with multiple resonances which is able to enhance detection sensitivity. A coaxially aligned readout circuit, positioned outside the GIS, interrogates the PD sensor to wirelessly obtain the PD signal. The proposed sensing scheme improves signal-to-noise ratio and ensures minimal disruption to the electric field distribution inside GIS. An experimental setup was established in a controlled laboratory environment to benchmark the multi-resonant sensor against the commercial UHF sensor. A 2.5-times enhancement of signal strength was observed. Since our sensor was implanted inside the GIS, a high signal-to-noise ratio (68.82 dB) was obtained. Moreover, we constructed a wireless calibration test to investigate the accuracy of the proposed sensor. The precision of the signal test was as high as 0.72 pC. The pulse phase distribution information was collected to demonstrate a phase-resolved partial discharge (PRPD) pattern. The experiment results validate the effectiveness of the proposed method and demonstrate excellent performance in PD detection.