Your browser doesn't support javascript.
loading
A simple new approach for mapping an ultrasonic tank for sonochemistry.
Mason, Timothy J; Ghimpeteanu, Daniela; Calinescu, Ioan; Vinatoru, Mircea; Trifan, Adrian.
Afiliación
  • Mason TJ; College of Engineering, Environment and Science, Coventry University, Coventry, United Kingdom.
  • Ghimpeteanu D; Bioresource Department, Politehnica Bucuresti National University of Science and Technology, RO-060042, Bucharest, Romania.
  • Calinescu I; Bioresource Department, Politehnica Bucuresti National University of Science and Technology, RO-060042, Bucharest, Romania.
  • Vinatoru M; Bioresource Department, Politehnica Bucuresti National University of Science and Technology, RO-060042, Bucharest, Romania.
  • Trifan A; Bioresource Department, Politehnica Bucuresti National University of Science and Technology, RO-060042, Bucharest, Romania. Electronic address: adrian.trifan@upb.ro.
Ultrason Sonochem ; 107: 106940, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38830324
ABSTRACT
The most used piece of equipment for sonochemistry is the ultrasonic cleaning bath. However, what is sometimes forgotten by scientists new to sonochemistry is the vital importance of the shape and positioning of any reaction vessel in the bath to obtain the most efficient and reproducible results. In experiments using an ultrasonic bath, a glass vessel (reactor) is inserted into the water contained in the bath. The water acts as the coupling medium for the transfer of acoustic energy from the transducer to the vessel (termed indirect sonication). The position of the reaction vessel above the base of the US bath can change the energy transmitted into it over a wide range of values (in our system between 100-500 J). We have carried out a study of the vertical distribution of the ultrasound field in a common type of ultrasound bath, comparing conventional sonochemistry dosimeters with a new and very simple approach using the Ultrasonic Capillary Effect (UCE) which can be performed in any laboratory. The technique involves the use of a capillary tube, to locate the vertical positions of acoustic pressure maxima above a single transducer on the base of the bath. The results are compared with those obtained using calorimetry, iodimetry, a cavitometer and the perforation of aluminium foil. The results show that the optimum position for the reaction vessel can be located very simply using UCE.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ultrason Sonochem Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido